Rice Lake CLS-M2 Скачать руководство пользователя страница 3

CLS-M2 Troubleshooting Guide

3

Weight on forks, no displayed 
weight.

Material, like wood debris, between the scale 
and the forklift carriage.

Remove debris

Material, like wood debris, between the front 
and back scale plates.

Remove debris

Centering pin touching the forklift carriage, 
causing it to teeter back and forth.

Adjust scale carriage, centering pin should 
not touch on sides and bottom.

Bottom cleats not adjusted properly. 

Adjust to proper gap using jam nuts, 0.02"

Low forklift battery.

Charge forklift battery.

Coiled cable error

Check coiled cable connections wand wear 
and tear.

If all these steps do not resolve your issue, check the following,

J-box sealing switch is in calibration mode.

Move switch to weighing mode.

Load cell connections on j-box loose.

Securely fasten connections.

J-box error

Open j-box and look for obvious damage.

Load cell errors

Test mV/v levels, at 1.5 mV per 1,000 lb, test 
ohms.

Calibration is required.

Calibrate the scale using Revolution.

COMPOW Box LEDs

Power Supply PCB

Green LED “PWR LED1” 

On

COMPOW box turned on, power from 
battery cable is good.

On, blinking

Check power cable for short.
Check for low battery voltage.

Off

Turn COMPOW box power switch ON.
Check fuses on battery connection and 
power supply PCB.

Low forklift battery

Replace power supply PCB

USB/Bluetooth PCB

Green LED “HB LED4”

 

On

J-box is transmitting valid data.
Coiled cable and j-box are working.

On, solid

Change j-box

Off

Check coiled cable and tighten connections.

Check power switch.

Check PWR LED1

Check load cell connections.

Check j-box.

Red/Green LED “RS-232 LED5” 

On, blinking

Responding to commands from VIRTUi2.
VIRTUi2 interface configuration.

Off

Not responding to commands from VIRTUi2 
software.
Restart VIRTUi2 configurator.

Symptom

Possible Cause

Action