Rice Lake CLS-M2 Скачать руководство пользователя страница 1

July 22, 2013

156791

CLS-M2 Forklift Scale

Troubleshooting guide

PN 151718

Symptom

Possible Cause

Action

Scale displaying negative weight

Forks are resting (even slightly) on the floor.

Lift forks up off floor.

Scale reading high against test 
weight.

Material, like wood debris, between the scale 
and the forklift carriage.

Remove debris.

Material, like wood debris, between the front 
and back scale plates.

Remove debris.

Centering pin touching the forklift carriage, 
causing it to teeter back and forth.

Adjust scale carriage, centering pin should 
not touch on sides and bottom.

Bottom cleats not adjusted properly or loose. Adjust to proper gap using jam nuts, 0.02”

If all these steps do not resolve your issue, check the following,

J-box error

Open j-box and look for obvious damage

Load cell errors

Test mV/v levels, at 1.5 mV per 1,000 lb, test 
at 350 ohms

Calibration is required

Calibrate the scale using Revolution

TM

Scale reading low against test 
weight.

Zero key has been pressed with a negative 
weight reading, while forks are on the floor.

Lift forks off ground, press the Zero key

Material, like wood debris, between the scale 
and the forklift carriage.

Remove debris

Material, like wood debris, between the front 
and back scale plates.

Remove debris

Centering pin touching the forklift carriage, 
causing it to teeter back and forth.

Adjust scale carriage, centering pin should 
not touch on sides and bottom.

Bottom cleats not adjusted properly or loose. Adjust to proper gap using jam nuts, 0.02"

If all these steps do not resolve your issue, check the following

J-box error

Open j-box and look for obvious damage.

Load cell errors

Test mV/v levels, at 1.5 mV per 1,000 lb, test 
at 350 ohms

Calibration is required

Calibrate the scale using Revolution.