CLS-680 Old Dominion Installation Detail
© Rice Lake Weighing Systems
●
All Rights Reserved
3
Connect Power Cable to Low Voltage Disconnect (LVD)
1. Locate the LVD or power wire connected to the LVD wire (commonly blue, labeled power).
The LVD should already be installed (
). LVD might be out of sight so a power wire should be available (
).
If unable to locate LVD connection, consult with forklift service technician or service manager to verify LVD is installed.
2. Connect the red wire from the indicator power supply cable to LVD instead of connecting directly to battery connection.
3. Connect the black wire from the indicator power supply cable to the battery ground.
4. Connect the blue wire from the indicator power supply cable to the forklift chassis.
Figure 5. Connect CLS-420 Indicator Wire to the LVD
Figure 6. Purkeys Dual Shield LVD, Supply Power Terminal Location
Wire Color
Signal
Red
Low Voltage Disconnect (LVD)
Black
Negative on battery
Blue
Chassis ground
Table 1. CLS-420 Indicator Power Supply Cable Connections
Note
Low Voltage Disconnect (LVD)