MSI-3460 Challenger 3
4
Visit our website
2.0
Operation
The following sections describe the basic operation of the MSI-3460.
If a function key does not work as expected, it is probably not set up to support the key.
For example, if the Function Key is set for TOTAL, the TOTAL mode must also be set up in the Setup Menu.
2.1 Power
To turn on the power, press
. The following displays in order:
• LED lights all segments at full brightness as a display test
• Display brightness changes to the setting determined in the display menu
• Software version number displays
• The unit enters
Weigh
mode
2.2 Zero
Press
to take out small deviations in zero when the scale is unloaded. For zeroing (taring) package or pallet weights,
see
. The zero key can be used in
GROSS
or
NET
mode.
The backup memory in the unit stores the zero reading and retains it even if the power fails.
Zeroing while in net mode will zero the gross weight causing the display to show a negative tare value.
The scale must be stable within the stable window.
The unit will only zero if MOTION annunciator is off and there has been no activity for two seconds.
The scale will accept a zero setting over the full range of the scale (NTEP and other Legal for Trade models may have
a limited zero range).
Zero settings above 4% of full scale will subtract from the overall capacity of the unit.
Example: If 100 lb on a 1000 lb scale is zeroed, the overall capacity of the scale will reduce to 900 lb, plus the
allowed over-range amount.
Note
POWER
ZERO
Note
Содержание Challenger 3 MSI-3460
Страница 1: ...MSI 3460 Challenger 3 Technical Manual PN 152161 Rev F June 24 2021...
Страница 44: ...MSI 3460 Challenger 3 40 Visit our website www RiceLake com...