Rice Lake Benchmark HD Series Скачать руководство пользователя страница 5

Introduction

1

1.0

Introduction

This manual provides reference information to install and wire the Benchmark HD series single-point benchtop

scale which is shown in Figure 1-1.

Figure 1-1. Benchmark HD Series Bench Scale

This NTEP-approved bench scale is available in a 30" x 30" and 36" x 36" platform with capacities from 250 to

500 lbs. Both capacities come standard with a potted single point load cell that is environmentally sealed. It also

comes with a standard ten feet of load cell cable. The heavy duty capacity scale is constructed with a 304 stainless

steel cover and mild steel frame construction to withstand many years of rugged use. 

1.1

Safety

Safety Signal Definitions:

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious 
injury.

Indicates a potentially hazardous situation that, if not avoided could result in serious injury or 
death, and includes hazards that are exposed when guards are removed.

Indicates a potentially hazardous situation that, if not avoided may result in minor or moderate 
injury.

Indicates information about procedures that, if not observed, could result in damage to
equipment or corruption to and loss of data.

General Safety

Do not operate or work on this equipment unless you have read and understand instructions in the
manual. Failure to follow the instructions or heed the warnings could result in injury or death. Contact
any Rice Lake Weighing Systems dealer for replacement manuals. Proper care is your responsibility. 

Failure to heed may result in serious injury or death.

DO NOT allow minors (children) or inexperienced persons to operate this unit.
DO NOT operate without all shields and guards in place.
DO NOT jump on the scale.
DO NOT use for purposes other then weight taking.
DO NOT place fingers into slots or possible pinch points.
DO NOT use any load bearing component that is worn beyond 5% of the original dimension.
DO NOT use this product if any of the components are cracked.
DO NOT exceed the rated load limit of the unit.
DO NOT make alterations or modifications to the unit.
DO NOT remove or obscure warning labels.

Keep hands, feet and loose clothing away from moving parts.

DANGER

WARNING

CAUTION

Important

WARNING

Содержание Benchmark HD Series

Страница 1: ...Benchmark HD Series Heavy Duty Bench Scale Installation Manual 93631...

Страница 2: ...4868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 www ricelake com www ricelake mx www ricelake eu www ricelake co in m ricelake com Rice Lake Wei...

Страница 3: ...ment 7 5 2 Replacement Parts 8 Benchmark Series Limited Warranty 10 Technical training seminars are available through Rice Lake Weighing Systems Course descriptions and dates can be viewed at www rice...

Страница 4: ...ii Benchmark HD Series Rice Lake continually offers web based video training on a growing selection of product related topics at no cost Visit www ricelake com webinars...

Страница 5: ...f not avoided may result in minor or moderate injury Indicates information about procedures that if not observed could result in damage to equipment or corruption to and loss of data General Safety Do...

Страница 6: ...n 5 point independently adjusted Cable Length 10 ft 3 m 6 wire shielded Output Impendance 350 Maximum Overload 200 Compensated Temperature Range 10 C 14 F to 40 C 104 F Dimensions Capacities Size Capa...

Страница 7: ...t the four corner feet until the scale is level and all feet contact the support surface so that the scale does not rock Lock the jam nuts on the feet when the final level is correct 2 2 Connecting th...

Страница 8: ...icator To prevent this all bench scales should be adequately grounded so that static charges and transient electrical surges can drain directly to the ground A recommended practice is to connect the s...

Страница 9: ...mes before calibration to be certain that everything is seated To calibrate the Benchmark HD scale place test weights on the scale platform equal to 70 100 of the scale s capacity If several weights a...

Страница 10: ...st the digital averaging of the indicator to minimize the erratic display Scale is not level Level the scale Water damage to the load cell or load cell cable Replace the load cell Faulty indicator Ser...

Страница 11: ...to 200 in lbs 11 Turn the scale upright Position the spacer plate on the load cell then place the top frame into position 12 Screw in the four upper load cell screws NOTE Torque bolts to 200 in lbs 1...

Страница 12: ...8 Benchmark HD Series 5 2 Replacement Parts Figure 5 2 Benchmark HD Assembly Drawing Breakout...

Страница 13: ...49788 8 3 15 Lock washer 5 16 regular 15153 8 4 Top frame 93758 30 x 30 93760 36 x 36 1 5 Self adhesive bumper 26407 30 36 6 Shim 3 16 x 2 3 8 x 3 SST 87358 2 7 Load cell 91690 250 lb scale 91692 500...

Страница 14: ...caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modified...

Страница 15: ......

Страница 16: ...868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 www ricelake com www ricelake mx www ricelake eu www ricelake co in m ricelake com Rice Lake Weig...

Отзывы: