820i Programmable HMI Indicator/Controller
74
Visit our website
SETPTS Menu
Parameter
Choices
Description
Level 2 submenus
SETPT 1–
SETPT 100
OFF
GROSS
NET
–GROSS
–NET
ACCUM
ROC
+REL
–REL
%REL
RESREL
PAUSE
DELAY
WAITSS
COUNTER
AUTOJOG
COZ
INMOTON
INRANGE
BATCHPR
TIMER
CONCUR
DGIN
AVG
TOD
DELTA
CHKWEI
PLSCNT
PLSRAT
ALWAYS
NEVER
DINCNT
Specifies the setpoint kind.
GROSS, NET, –GROSS, –NET, ACCUM, ROC, +REL, –REL, %REL, RESREL. DIGIN, DINCNT,
AVG, and TOD setpoint kinds can be used as either batch or continuous setpoints.
PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG, DELTA, PLSCNT, ALWAYS, and NEVER setpoint
kinds can only be used in batch sequences.
COZ, INMOTON, INRANGE, BATCHPR, TIMER, CONCUR, PLSRAT, and CHKWEI setpoint kinds
can only be used as continuous setpoints.
See Table 8-1 for more information about setpoint kinds.
BATCHNG
OFF
AUTO
MANUAL
Batching enable. Set to AUTO or MANUAL to allow a batch sequence to run. MANUAL requires a
BATSTRT digital input, BATSTART serial command,
Batch Start
softkey, or the StartBatch function
in an
iRite-IDE
program before the batch sequence can run. AUTO allows batch sequences to repeat
continuously.
Table 8-2. Setpoint Menu Parameters