![Rice Lake 380 Synergy Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/rice-lake/380-synergy/380-synergy_technical-manual_1453824054.webp)
380 Synergy Digital Weight Indicator
48
Visit our website
Digital Rolling Average Filter Procedure
1. In setup mode, set the rolling filter stage parameters (
DGFLTR1-3
) to 1.
2. Set
DFTHRH
to
NONE
.
3. Return to weigh mode.
4. Remove all weight from scale, then watch the indicator to determine the magnitude of vibration effects on the scale.
5. Record weight below which all but a few readings fall. This value is used to calculate the
DFTHRH
.
Example – if a heavy-capacity scale (10000 x 5 lb) produces vibration-related readings of up to 50 lb, with occasional
spikes up to 75 lb, record 50 as the threshold weight value.
6. Place the indicator in setup mode and set the filter stage parameters (
DGFLTR1-3
) to eliminate the vibration effects on
the scale (leave
DFTHRH
set to
NONE
).
7. Find the lowest effect value for the
DGFLTR1-3
parameters.
If needed, the digital filter cutout sensitivity (
DFSENS
) and the digital filter cutout threshold (
DFTHRH
) can be used to reset the
digital rolling average filter so the response to a rate change is faster.
8. Calculate the
DFTHRH
parameter value by converting the weight value recorded in
(
Threshold_Weight_Value / Display_Divisions
).
, with a threshold value of 50, and a display divisions value of 5, set the DFTHRH parameter to
10 display divisions.
9. Set the
DFSENS
parameter high enough to ignore transient peaks. Longer transients (typically caused by lower
vibration frequencies) causes more consecutive out-of-band readings; set the
DFSENS
parameter higher to counter
low frequency transients.
10.5.2 Regulatory Mode Functions
Regulatory
Parameter
Weight On
Scale
Tare In
System
Front Panel
Key Tare
Front Panel
Key Zero
NTEP
Zero
No
“000000”
Zero
Yes
Clear tare
Zero
Negative
No
No action
Zero
Yes
Clear tare
Zero
Positive
No
Tare
Zero
Yes
Tare
Zero
Canada
Zero
No
“000000”
Zero
Yes
Clear tare
Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Clear tare
Positive
No
Tare
Zero
Yes
No action
Clear tare
OIML
Zero
No
“000000”
Zero
Yes
Clear tare
Zero and Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Zero and Clear tare
Positive
No
“000000”
Zero
Yes
Tare
Zero and Clear Tare
None
Zero
No
“000000”
Zero
Yes
Clear tare
Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Clear tare
Positive
No
Tare
Zero
Yes
Clear tare
Clear tare
Table 10-3. Tare and Zero Key Functions for REGULA Parameter Settings