The 380 can be calibrated using the front panel or EDP commands. The following sections describe the procedures required for
these calibration methods.
CAL jumper must be removed to perform calibration.
The 380 requires a WZERO and WSPAN points to be calibrated. The linear calibration points are optional; they must
fall between zero and span, but must not duplicate zero or span.
Figure 5-1. Calibration Menu
5.1 Front Panel Calibration
5.1.1 Span Calibration
Use the following steps to perform a standard span calibration on a connected scale.
1. Access the setup menu by pressing
momentarily during power up.
Setup
displays.
CAL jumper must be removed to perform calibration.
2. Press
once.
config
displays
3. Press
twice.
Calibr
displays.
4. Press
.
wzero
displays.
See
if the application requires a rezero, last zero or temporary zero.
5. Ensure there is no weight on the scale.
6. Press
to perform a zero calibration.
ok
displays.
7. Press
.
ZROCNT
for more information on
ZROCNT
.
8. Press
.
wval
displays.
9. Press
. The current test weight value displays.
10. Enter a new value, if necessary. See
for more information on numeric entry.
11. Press
to accept value.
wSpan
displays.
12. Place the specified amount of test weight on the scale.
13. Press
to perform a span calibration.
ok
displays.
14. Press
.
SPNCNT
displays. See
for more information on
SPNcnt
.
Span calibration is complete. To continue with a linear calibration, see
before returning to
weigh mode.
15. Press
three times to return to weigh mode.
Note
Setup
Calibr
zrocnt
WZERO
WVAL
spncnt
WSPAN
Point 1-4
WLIN
REZERO
Wlin v1-4
wlin c1-4
wlin f1-4
lstzro
tmpzro
ZERO
Note
GROSS
NET
B/N
GROSS
NET
B/N
Note
GROSS
NET
B/N
TARE
T
GROSS
NET
B/N
TARE
T
GROSS
NET
B/N
TARE
T
Note
ZERO
Содержание 380 Synergy
Страница 1: ...380 Synergy Digital Weight Indicator Technical Manual PN 201481 Rev B September 17 2021...
Страница 59: ......