If the power cable or extension cord is damaged or cut during operation, immediately disconnect plug 
from its main power source. Do not touch the cable or extension cord before unplugging from main 
power. 

 
 

IV. GETTING STARTED 

 

 

Before  any  intervention  on  product,  ensure  that  product  is  disconnected  form  its 
power source. 

 

4.1- Unpacking 

Remove product from its packaging. 
Check that product and accessories are not damage  
 

4.2- Installation 
Attention

: before installing check that the technical specifications of the device, the pump and the 

system are all compatible. 
 
The pressure generated by the pump must be at least 0.5-1.0 bar greater than the restart pressure of 
the device. 
The effective pressure of the pump and the height of the water column of the system influence the 
device and must be checked in relation to the restart pressure: 
Restart pressure 1.5 bar (0.15 MPa)  
The water column between the device and the highest service must not exceed 15 meters. 
In the event of the height of the water column exceeding the level indicated, the pump will be enabled 
without starting up. To overcome these problems install the device at a higher level in order to 
recreate the above-mentioned conditions. 
The device may be installed : 

- directly onto the pump (see Fig.3): screw unit on pump outlet. 
- or between the pump and the first service (see Fig.4): connect unit to suction line. 

Advice: the connections assembly (suction hose and discharge hose) must be sealed with hemp or 
Teflon or thread sealing tape so that the sealing is perfect. 
If the input pressure of the device exceeds 10 bar (1 MPa), install a pressure reducer between the 
pump and the device itself. 
No tap can be installed between the pump and the device (see Fig.2 point 3) 
It is imperative to install the device with the flow direction arrows pointing upwards 
It is recommended to install a ball valve and a manometer at the output of the device to control the 
operation of the pump and the device excluding the system by means of the valve, and checking the 
effective extraction of the pump with the manometer. 
It is also recommended to connect the output of the device to the system by means of a flexible tube 
Before starting the device check that the pump is correctly primed. 
 

4.3- Electrical connections 

The electrical connections must be carried out by qualified personnel and in compliance with local 
regulations in force.  
It is always advisable to provide for the installation of an omnipolar switch upstream from the device 
with a minimum opening of the contacts equal to three millimeters. 
• Check the mains voltage and the nameplate data of the pump motor. 
• Carry out the electrical connections. 
 

- connect the pump's power plug to the unit’s socket (7) 

- connect the unit’s power plug to a mains socket outlet (220-240V). 

• Make sure that the device is grounded. 

Содержание RIBILAND PRPCTRLPRO

Страница 1: ...TIC PUMP CONTROL User and maintenance manual IT REGOLATORE ELETTRONICO Manuale di istruzioni e di manutenzione Réf Art Nr PRPCTRLPRO 519806 Imp Par by Ribimex SA 56 Route de Paris RN4 FR 77340 Pontault Combault Imp da Ribimex Italia s r l Via Igna 18 36010 Carrè Vi Italia v3_2016 01 07 ...

Страница 2: ...ouvoir le consulter ultérieurement WARNING Carefully read this instruction manual before operating this appliance Incorrect operation may cause injury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto può causare lesioni e o danni Conservare il presente manuale per fu...

Страница 3: ...t ou de détérioration du produit en cas de non respect des consignes Lire le mode d emploi Tenir les personnes spécialement les enfants et animaux à distance du produit et de la zone de travail Débrancher le produit de sa source d alimentation avant toute opération d entretien de nettoyage ou intervention sur le produit ou lorsque vous n utilisez pas le produit Débrancher immédiatement le produit ...

Страница 4: ...ec le produit 5 Ranger le produit en état de repos Lorsqu il n est pas utilisé il est recommandé de ranger le produit dans des locaux secs de le placer hors de portée des enfants soit en hauteur soit sous clef 6 Ne pas forcer le produit Le produit travaillera mieux et sera plus sûr à la vitesse et à l usage pour lesquels il est prévu N utilisez pas ce produit pour des travaux auxquels il n a pas é...

Страница 5: ...ue de blessures des personnes et animaux et de dommages aux biens L utilisateur et ou l opérateur du produit sont seuls responsables des dommages et blessures causés aux biens et aux personnes 21 Faire réparer le produit par du personnel qualifié Sauf indications contraires dans les instructions il est recommandé de faire réparer correctement ou remplacer par un service agréé toute pièce endommagé...

Страница 6: ... 0 5 à 1 bar supérieur à la pression de redémarrage de l appareil Notamment la pression effective de la pompe et la hauteur de la colonne d eau de l installation pesant sur l appareil doivent être contrôlées en rapport à la pression de redémarrage Pression de redémarrage 1 5 bar 0 15 MPa La colonne d eau entre l appareil et le dispositif d utilisation le plus haut ne doit pas dépasser 15 m Au cas ...

Страница 7: ...régulateur est situé un panneau qui affiche les phases de fonctionnement au moyen de témoins lumineux témoin LED 3 b Power On le contrôleur est sous tension témoin LED 3 c Failure défaut témoin LED 3 d Pump On la pompe est en marche Au moment du branchement au réseau électrique le témoin 3 b s allume puis le témoin 3 d signalant le démarrage de la pompe Celui ci reste en marche pendant quelques se...

Страница 8: ...au ou un quelconque liquide 6 2 Entreposage il est recommandé de ranger le produit dans un local sec de le placer hors de portée des enfants soit en hauteur soit sous clef 6 3 Mise au rebut En fin de vie ne pas jeter le produit avec les ordures ménagères ou dans l environnement Apporter le produit à une déchetterie ou à un centre de collecte des déchets des équipements électriques et électroniques...

Страница 9: ... or moisture Caution Risk of injury and or damage and or deterioration of product in case of non compliance to safety requirements Read the instructions manual Keep persons esp children and animals away from product and working area Disconnect product from its power source before maintenance cleaning ou any intervention on product or when you do not use product Disconnect product from its main pow...

Страница 10: ...will do the job better and safer at the rate speed for which it is intended Do not use the product for purposes other than those for which it is intended The product will do a better and safer job if it is used only for the purposes it was designed for 7 Use the right product Do not force small product or attachment to do the job of a heavy duty product 8 Dress properly Do not wear loose clothing ...

Страница 11: ...Repairs should only be carried out by qualified persons using original spare parts otherwise this may result in considerable danger to the user 22 Remarks The safety precautions and instructions given in this manual are unable to cover in detail all the conditions and situations that may arise The operator and or user must use common sense and caution when operating the product especially for any ...

Страница 12: ...he pump and the first service see Fig 4 connect unit to suction line Advice the connections assembly suction hose and discharge hose must be sealed with hemp or Teflon or thread sealing tape so that the sealing is perfect If the input pressure of the device exceeds 10 bar 1 MPa install a pressure reducer between the pump and the device itself No tap can be installed between the pump and the device...

Страница 13: ...set button pressed and wait with a service e g tap open until the red light turns off After the service e g tap is closed the device stops the pump and goes into standby mode the Power ON LED lights on ready to carry out in complete autonomy all the subsequent command and control operations On opening a service e g tap watering the device starts the pump which remains in operation for as long as t...

Страница 14: ...se the product with household garbage Do not throw into the environment Dispose of the product in a collection centre for waste of electrical and electronic equipment or a waste drop off centre or seek advice from your local municipality Disposal of the product accessories and packaging should be carried out according to local regulations governing environment protection ...

Страница 15: ...i e o deterioramento dell attrezzo in caso di non conformità ai requisiti di sicurezza Leggere il manuale d istruzioni Tenere persone esp bambini e animali lontani dal prodotto e dall area di lavoro Staccare il prodotto della sua alimentazione prima di qualsiasi operazione di cura di pulizia o intervento sul prodotto o quando non utilizzate il prodotto Scollegare il cavo elettrico se il cavo o il ...

Страница 16: ...no essere conservati in una stanza asciutta e chiusa a chiave non accessibile ai bambini 6 Non sovraccaricare il prodotto Il lavoro sarà migliore e più sicuro se si rispetta la gamma di applicazione specificata 7 Utilizzare l utensile corretto Non usare utensili o accessori troppo deboli per lavori pesanti Non usare utensili per scopi diversi da quelli per cui sono destinati 8 Indossare abbigliame...

Страница 17: ...are il rischio di lesioni alla persona ed animali e di danni ai beni L utente e o l operatore dell attrezzo sono soli responsabili dei danni e ferite causati ai beni ed alle persone 21 Le riparazioni devono essere eseguite solo da un elettricista qualificato Parti danneggiati devono essere riparati o sostituiti da un officina di assistenza se non diversamente indicato nelle istruzioni sul funziona...

Страница 18: ...imo secondo le indicazioni che seguono Pressione di ripartenza 1 5 bar 0 15 MPa La colonna d acqua tra l apparecchio e l utilizzo più alto non deve superare 15 metri Qualora l altezza della colonna d acqua superi le quote sopra indicate la pompa si avvia ma non riparte Per eliminare l inconveniente è sufficiente posizionare più in alto l apparecchio per ricreare le condizioni sopra esposte L appar...

Страница 19: ...ia 3 d che segnala l avviamento della pompa cuesta rimane in funzione per alcuni secondi al fine di permettere all impianto di andare in pressione Qualora questo tempo risultasse insufficiente si accende la spia 3 c in questo caso tenere premuto il pulsante rosso Reset riarmo ed attendere con un utilizzo aperto che si spenga la spia 3 c Chiuso l utilizzo l apparecchio ferma la pompa e si pone in p...

Страница 20: ... il dispositivo con i rifiuti domestici o nell ambiente Portare il prodotto ad un centro per il trattamento dei rifiuti o ad un centro di raccolta degli scarti delle attrezzature elettriche ed elettroniche o informatevi al vostro comune Effettuare lo smaltimento del prodotto degli accessori e dell imballaggio conformemente alle regolamentazioni locali relative alla protezione dell ambiente natural...

Страница 21: ... c LED che indica una avaria 3 d LED di tensione della pompa 4 Copertura della presa 5 Ingreso 6 Manometro 7 Presa per collegare la pompa Fig 2 1 Si la colonne d eau entre la pompe et le robinet dépasse 15m le contrôleur A ne peut pas être installé directement sur la pompe H Il doit être élevé jusqu à ce que la colonne d eau entre le contrôleur et le robinet ne dépasse pas 15m 2 Le contrôleur A es...

Страница 22: ...efore starting the unit check the suction and ensure that pump is primed 6 The unit can be installed directly on the pump Fig 3 or between the pump and the first tap Fig 4 7 It is imperative to install the unit with the arrows on the upward position 8 It is advisable to connect the unit outlet to the system by means of flexible hose E supera 15m 2 Il dispositivo di controllo A è fornito d una valv...

Страница 23: ...Page 23 23 Fig 3 Fig 4 Fig 5 ...

Отзывы: