Page 32 / 38
minutes maximum).
h) Fluids permitted / Fluids not permitted
Permitted
Not Permitted
Related Dangers
• Diesel fuel at a viscosity
from 2 to 5.35 cSt (at a
temperature of 37.8°C).
Minimum flash point (PM)
55°C.
• Gasoline
• Inflammable liquids with PM
<55°C.
• Liquids with viscosity >20 cSt.
• Water
• Food liquids
• Corrosive chemical products
• Solvents
• Fire - explosion
• Motor overload
• Pump oxidation
• Pump contamination
• Pump corrosion
• Injury
• damage to gasket seals
4.3- Important recommendations
Before connecting to the power source, you must observe the following:
- The device must be placed on a horizontal, leveled surface that is sufficiently capable of supporting the
total weight of the device when filled with liquid.
- Make sure that the power supply corresponds with the connection specifications of the device (see rating
label).
- To prevent vibrations, the device should be placed on an elastic support (e. g. a rubber mat).
- The installation site must be well ventilated and protected from the effects of weather.
- When being used on garden ponds and swimming pools, the device must be set up so as to guard against
overflowing and protected against falling in.
- Additional legal requirements must be observed
- When operating indoors you must ensure that there is a drain in the floor or a leak prevention
mechanism.
- Before starting up, check the suction hose to ensure that it is sealed. Bubbles of air in the suction hose
are an indication that there may be leaks and may lead to failure of the device.
WARNING!
- The warranty does not cover accidents due to improper installation. This pump must be installed in
accordance with local standards and by a qualified person (we recommend you to contact an electrician).
- The fixed pipeline that will connect the pump must include a separation device having contacts with the
opening distance of at least 3 mm in all poles.
- When operating in swimming pools, garden ponds and similar places, the device must be provided with
a residual current of not more than 30 mA by means of a residual-current-operated protective device
- The total head must not exceed ?? m.
- The cable must be at least one cable H05 RN-F 3×1mm2 (or exceed 1mm2) (line, neutral and earth)..
4.4- Electrical connection
a) Make sure that the power supply corresponds with the connection specifications of the device (see
rating label).
b) Check that the power cable is not damaged.
c) Connect plug to a wall socket 10/16A fitted with a ground connection.
d) Turn the pump for 2 to 3 seconds to perform a dry run of the pump.
Do not operate the pump without liquid for more than 2 to 3 seconds to avoid overheating. This will cause
permanent damage.
e) Disconnect the pump from the power supply (remove the plug from the wall socket), and then proceed
with suction and delivery line connection, as described in the following paragraphs.
f) Ensure that the electrical connection is protected against water splashing.