3
PRE-INSTALLATION CHECK
For doors with a total width up to 6 m, maximum height 2,5 m or a total surface area of 12 square metres and door lever’s
length with maximum length 83 cm, 2 BOSS (MASTER A SLAVE AA40835) device should be used; mounted as
shown in Fig. 3, with a PAIR OF STRAIGHT LEVERS code ACG8720 (or a PAIR OF CURVED LEVERS code ACG8722), the
accessories for LATERAL TRANSMISSION for 2 operators cod. ACG8715 and 2 SHORT MOUNTING PLATE codes ACG8189 or
2 LONG MOUNTING PLATE codes ACG8188.
- Check that the available space between the moving frame of the door and external frame with counterweights exceeds 15
mm. If so, the STRAIGHT LEVERS can be mounted. Otherwise, mount the CURVED LEVERS if the distance is less than 15
mm, making sure to remain within the assembly parameters described in Fig. 4.
- Check that the up-and-over door slip bearings are not blocked or obstructed and that the counterweight fastening cables
are in correct working order.
- Remove, if present, the manual closing lever connected to the locking device.
N.B.
It is obligatory to uniform the characteristics of the door to the standards and laws
in force. The door can be automatized only if in a good state and if in accordance
with EN 12604 standard.
No trapping points must be generated (for example between horizontally pivoted open
door and wall).
33
G
B
Parts to install according to EN 12453 standard
COMMAND TYPE
USE OF THE SHUTTER
Skilled persons
(out of public area*)
Skilled persons
(public area)
Not skilled
persons
Hold-to-run operation
A
B
Not possible
Impulsive - in sight
(e.g. push-button)
C or E
C or E
C and D, or E
impulsive - out of sight
(e.g. remote)
C or E
C and D, or E
C and D, or E
automatic
C and D, or E
C and D, or E
C and D, or E
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
6
5
4
1
6
1 -
1 BOSS MASTER op 1
BOSS SLAVE operator
2 - Aerial
3 - Blinker
4 -
BLOCK Wi-Fi key selector
5 -
FOTOCOSTA Photoelectric
strip
6 -
Photoelectric cells (internal)
2
3
The door lever’s length
cannot exceed the 83 cm
BOSS MASTER
BOSS SLAVE
Содержание AA40836
Страница 14: ...14 61 62 58 59 60 63 I BOSS MASTER BOSS SLAVE ...
Страница 28: ...28 F 61 62 58 59 60 63 BOSS MASTER BOSS SLAVE ...
Страница 42: ...42 G B 61 62 58 59 60 63 BOSS MASTER BOSS SLAVE ...
Страница 46: ...NOTES 46 ...