Rhopoint Optimap PSD Скачать руководство пользователя страница 8

Operation 

Main Measurement Screen 

 
 

 

 
 

 

The  touch  sensitive  icon  based measurement  screen provides  operation  and  setup 
of the device. 

By  pressing  each  of  the  icons  or  active  areas  shown  on  the  screen  the  instrument 
responds in a different way according to the function. 

To the left of the screen there are six white range selector indicators displayed 
showing the measurement scale selected.  
Measurement data is displayed in each of these indicators according to the range 
selected which is shown above the texturemap window. 

In the example screen above the 0.1 – 30mm range has been selected in curvature 
mode K. The 3D texturemap screen displays an image of the surface according to 
this range. 

By pressing each of the indicators in turn the texturemap window changes to display 
the image according to the range selected allowing the analysis of any structures 
present on the surface in that range 

Results are also displayed in graphical or statistical format in the results window at 
the top of the screen.

 

Texturemap window 

Project Name 

Series 

Measurement 
Number 

Instrument 
Settings 

Sample Viewer 

Operate 

Results Window 

Range selector / 
display. 

Selectable as 
either curvature 
(K) or texture (T)

Measurement 
Direction 

Measurement 
Range 

Содержание Optimap PSD

Страница 1: ...his Rhopoint product Please read these instructions carefully before operating this product and retain them for future reference The images shown in this manual are for illustrative purposes only Engl...

Страница 2: ...they reserve the right to change information included in this document without prior notice Copyright 2013 Rhopoint Instruments Ltd All Rights Reserved Optimap and Rhopoint are registered trademarks...

Страница 3: ...2 Contents Storage and Handling 3 About the Optimap PSD 4 Accessories 4 Functional overview 5 Power 6 Switching on the unit 6 Operation 7 Measurement Principle 21 Instrument Specifications 23...

Страница 4: ...ure Ensure that the instrument is not exposed to moisture chemicals or to any corrosive vapours Do not hold the instrument by the measurement aperture no objects should be placed inside the aperture a...

Страница 5: ...er the surface as all measurements are made optically therefore preventing any damage during operation Although surface contact is required the devices measurement port is rubberised to protect it dur...

Страница 6: ...5 Functional overview Label No Function 1 Battery Indicator 2 Touch screen display 3 Power Sleep button 4 Battery charger connector 5 USB connector 6 Measurement Port 7 Carry Handle 3 4 1 2 5 6 7...

Страница 7: ...15 seconds to complete whereas a start from sleep will be almost instantaneous To switch the instrument on press and hold the Power Sleep button until two audible beeps the second of which is longer...

Страница 8: ...window In the example screen above the 0 1 30mm range has been selected in curvature mode K The 3D texturemap screen displays an image of the surface according to this range By pressing each of the i...

Страница 9: ...ed for these will differ according to application however it is the Project name that is the key field holding all measurement data for each series Therefore as an example a typical naming setup for a...

Страница 10: ...his is caused by insufficient light being reflected from the surface being measured to the sensing system A reflective model used on too dull a surface will usually cause this effect This can normally...

Страница 11: ...A reflective model is shown alternatively Extra Dull or Dull will be displayed if selected Press the Select icon the display will change to Use the keyboard to enter the name of the project press Ente...

Страница 12: ...e surface Failure to observe this will result in the Optimap making incorrect measurements Once completed the screen will return to the main measurement screen with the project name entered being disp...

Страница 13: ...t an error message will be displayed Delete Project Pressing this icon deletes the active project displayed in the project name window Stored projects can be selected using the Up Down selection icons...

Страница 14: ...reen is the same as the Project and Series screens Screens change in the same way as shown previously Returning to the Main Measurement Screen Texturemap window Project Name Series Measurement Number...

Страница 15: ...urement number indicator will increment by one as each measurement is made Sample Viewer Pressing the Sample Viewer icon allows viewing of the surface under different conditions There are four modes o...

Страница 16: ...Sample Viewer Y Sweep Projects a fringe pattern onto the surface in the Y direction Useful for pre measurement directional analysis of texture and or defects White screen Illuminates the entire surfa...

Страница 17: ...ing the Optimap to be accurately positioned on the area of interest Instrument Settings Pressing the Instrument Settings icon accesses the Settings Menu for configuration of the Optimap There are six...

Страница 18: ...sh German French and Spanish Languages are sequentially selected and displayed after each press Pressing the Date icon allows the date to be set Press the date required in the calendar and Exit to sav...

Страница 19: ...played on the Optimap Two options are available Curvature K or Texture T Band Select Data can be displayed in either dual band or multi band format Chart Type In the Results Window data can be display...

Страница 20: ...screen viewing of the sample surface Texturemap window Project Name Series Measurement Number Instrument Settings Sample Viewer Operate Results Window Range selector display Selectable as either curv...

Страница 21: ...om In tap repeatedly to zoom into image Zoom Out tap repeatedly to zoom out of image Instrument verification Due to the PSD measurement principle the Optimap requires no calibration It is recommended...

Страница 22: ...ed from the surface are spatially modelled to calculate the direction of the normal at each point across the surface thereby allowing the profile at that point to be obtained Displaying the sinusoidal...

Страница 23: ...Waviness scale regular equations are then applied to the filtered curvature data to produce a texture T scaling For this scale total texture T is used to represent the SD sigma of surface textures wit...

Страница 24: ...mm x 70mm Lateral Resolution 75 m Data storage 6GB Compact Flash 200 readings Data Transfer USB Memory Stick Go Suite Data Transfer Software Cable Power Rechargeable Lithium Ion Battery 4800mAH 4 8 ho...