Service, Maintenance and Hydraulic Settings 

* Use only filters with by-pass 

Hydraulic Settings 

Check the working pressure by means of test equipment. The test equipment must 
comprise a pressure gauge, a flow meter and a valve for adjustment of pressure. 

The pressure relief valve is placed on the right side of the valve block. 

1.  Connect the 

test equipment, start the powerpack and move the lever to “ON”. 

Then close the valve - the pressure gauge must show 2175 p.s.i.(150 bar). 

Adjust the pressure relief valve by loosening the lock nut and turning the 
adjustment screw in or out. “In” increases the pressure, and “out” decreases the 
pressure. 

Retighten the lock nut after adjustment. 

2.  When the pressure relief valve has been adjusted correctly, the working pressure 

must be set at 1450 p.s.i.(100 bar) by means of the valve on the test equipment. 
At 1450 p.s.i.(100 bar), the oil flow should be 5.28 (8.0) g.p.m.(20 (30) l. p.m.) 
power on request. 

On the powerpack with POR (Power on Request), the flow is adjusted by 
loosening the POR (Power on Request) cylinder in the bracket and pushing it to 
the left (higher flow) or to the right (lower flow). 

On the powerpack with adjustable flow, the flow is regulated by adjusting the 
position of the throttle cable. 

If correct pressure/oil flow cannot be achieved by following the 
above instructions, the powerpack must be re-adjusted. If the 
pressure/oil flow is then still incorrect, the pump is defect and 

must be replaced. 

 

Service/Maintenance 

Daily 

Weekly 

Yearly 

Engine oil 

Check 

 

1 x replacement 

Hydraulic oil 

Check 

 

1 x replacement 

Hydraulic oil filter * 

 

 

1 x replacement 

Check hoses 

 

(tighten up if needed) 

 

Air filter 

 

 

1 x replacement 

Fuel filter 

 

 

1 x replacement 

 

Содержание HPP13 Flex

Страница 1: ...or choosing Rhino Power Pack Please note that the Rhino Power Pack is delivered without hydraulic oil and therefore it must be filled up with hydraulic oil prior to operation To ensure smooth operatio...

Страница 2: ...Contents Page Safety precautions 2 Filling up hydraulic oil 2 Technical data 3 Starting instructions 4 Service maintenance and hydraulic settings 5 Oil types 6 Warranty conditions 7 1...

Страница 3: ...we recommend the use of a crane 7 The pressure relief valve is set at 2175psi 150 bar from our plant Never set it higher 8 Always use filters with by pass The use of filters without by pass may blow t...

Страница 4: ...pressure relief valve to avoid a too high pressure Furthermore the very efficient air cooling protects the powerpack against overheating 3 Oil flow 5 25 g p m 20 l p m at 2500 r p m 8 g p m 30 l p m a...

Страница 5: ...ke Turn ignition switch to 1 Pull recoil starter Move the lever to ON Stop Move the lever to OFF Turn off the ignition switch Turn the fuel tap to OFF Powerpack with adjustable flow The desired oil fl...

Страница 6: ...working pressure must be set at 1450 p s i 100 bar by means of the valve on the test equipment At 1450 p s i 100 bar the oil flow should be 5 28 8 0 g p m 20 30 l p m power on request On the powerpac...

Страница 7: ...rd hydraulic oil i e all types of mineral oil and biodegradable oil which comply with the followingvalues 6 Recommended viscosity ISO 32 20 40 cSt Permitted viscosity ISO 15 1000 15 1000 cSt Viscosity...

Страница 8: ...chase provided Rhino s obligation under this Limited Warranty is expressly limited to the repair or replacement at Rhino s election of such defective Hydraulic Tool s which is proved to be defective u...

Страница 9: ...7721140 Wheel cover 2 6 7721139 Wheel HPP13 18 2 7 7621042 Screw M8x10 10 8 8222361 Side cover set HPP13 13 FLEX 1 9 7621046 Screw M8x35 2 10 7621010 Lock nut M8 4 11 8721095 Rubber foot 1 12 9021563...

Страница 10: ...421060 Angle nipple 1 2 Loctite 542 1 15 7621173 Screw M10x40 Loctite 243 1 16 8221174 Supporting leg 1 17 8721166 Rubber damper M6x18 Loctite 638 1 18 7621171 Washer M8 8 19 7621043 Screw M8x110 Loct...

Страница 11: ...17 1 17 8221792 Spool 1 18 7721094 Lever ON OFF Loctite 243 1 19 7521072 Seal ring 1 2 6 26 7421587 Pressure relief valve 40 Nm 1 29 7401142 Q R coupling 1 2 BSP female 1 30 7401141 Q R coupling 1 2 B...

Страница 12: ...21044 Screw M8x16 4 15 7521608 O ring 13x2 mm 1 16 7621607 Retaining ring AV17 1 17 8221792 Spool 1 18 7721094 Lever ON OFF Loctite 243 1 19 7521072 Seal ring 1 2 6 20 7621029 Nut M6 1 21 9921656 Scre...

Страница 13: ...pipe 1 8 7621029 Nut M6 1 9 7521013 Seal 1 10 7521014 Seal 1 11 8221015 Guide element bronze 1 12 7521018 Seal ring POR 18 24x2 1 13 7521017 Seal ring 3 8 1 14 7421012 Fitting 3 8 x1 8 1 15 7621021 Wa...

Страница 14: ...2 4 7421079 Hose fitting 1 2 x3 4 1 5 7521118 Seal ring 3 4 1 6 7621045 Screw M8x30 Loctite 243 2 7 7421082 Hose clip 3 4 2 8 7621010 Lock nut M8 4 9 7621035 Washer M8 4 10 7621049 Screw M8x45 4 11 8...

Страница 15: ...21188 1 6 Filter cup 1 7 O ring 3x60 Included in 9421188 1 8 Filter housing 1 9 9421191 Ventilation filter Old type 1 9 9422041 Ventilation filter New type 1 10 9421192 Cover f ventilation filter Old...

Страница 16: ...ing 1 2 x3 4 1 3 7521118 Seal ring 3 4 2 4 7621047 Screw M8x90 3 5 8221121 Plate 1 6 7421582 Fitting 1 2 x3 4 1 7 8221116 Plate 1 8 8221086 Distance pipe 12x1 5 1 9 8321093 Cooler 280 12 1 10 8221112...

Отзывы: