Rhino Panic Pack
4. SPECIFICATIONS
Electrical
Supply Voltage:
16.5Vac, 20VA
Rated PSU Output:
1.2 A
Ripple:
<5%
Current:
<100mA quiescent
<150mA
in alarm.
Standby B
attery:
12.0V
SLA , 7Ah
Recharge Time:
24hr
Low V
oltage A
larm:
10.5V
Deep D
ischarge Cut-off:
9.5V
Fuses:
Mains: 3 15mA, 250V, 2 0mm
Auxiliary 1 2V: 900mA PTC
Battery: 1.6A PTC
On-board Zones:
6
Dedicated wired inputs
.
Wireless Remotes:
100 –
Numbered 0 to 9 9
Panel O
utputs 1 -2:
1A switched to 0V
Environmental
Operating Temperature:
-25°C +55°C
(-13°Ft o +131°F)
Storage Temperature:
-25°C to +60°C ( -13°Ft o +140°F)
Max. H
umidity:
95% non-condensing
EMC:
Residential, c ommercial and l ight industrial.
Do n
ot throw away the product with the normal household waste at the end
of its life, but hand it in at the o cial collection point for recycling. The
onboard battery also contains substances that may pollute the environment.
Always remove te battery before you discard and dispose of the battery at
an o cial collection point for batteries.
Physical
Dimensions:
21.5cm x 24.5cm x 7.5cm
Housing:
1mm Steel.
Packed Weight:
1200g
Standards
Safety
Conforms to European Union (EU) Low Voltage Directive (LVD) 2006/95/EC.
EMC
Conforms to European Union (EU) Electro-Magnetic Compatibility (EMC) Directive 2004/108/EC.