RHINO MOTION CONTROLS 

RMCS-1120  
Hybrid Servo Driver with Modbus RTU communication 
(Max. 50Vdc and 7A per phase)  

 

http://www.rhinomc.com 
 

Page 1 

 

Hybrid AC Driver [RMCS-1120] 

 

 

 

 

Installation Manual and Datasheet 

Содержание RMCS-1120

Страница 1: ...RHINO MOTION CONTROLS RMCS 1120 Hybrid Servo Driver with Modbus RTU communication Max 50Vdc and 7A per phase http www rhinomc com Page 1 Hybrid AC Driver RMCS 1120 Installation Manual and Datasheet...

Страница 2: ...tion for the motor outputs over voltage and under voltage protection and will survive accidental motor disconnects while powered up The RMCS 1120 delivers a low voltage servo performance using a field...

Страница 3: ...d by load Servo Loop Speed 500 1000 Hz Power Dissipation 0 15 Watts Short Circuit Current 7 10 Amps In case of motor terminal short PUL and DIR Voltage 2 5 7 Volts DC Between and input pins Ambient Te...

Страница 4: ...ve may damage the drive Voltage in excess of 7V between the PULSE and PULSE or DIR and DIR or ENA and ENA input terminals may damage the opto isolators Reverse voltage in excess of 7V between the PULS...

Страница 5: ...GREEN Motor Coil Phase A Terminal 4 A YELLOW Motor Coil Phase A Terminal 5 B WHITE Motor Coil Phase B Terminal 6 B BLUE Motor Coil Phase B Pulse and Direction Input Assignments Terminal No Terminal Na...

Страница 6: ...Direction RS 485 Command Port A 2pin command port is available on the drive for debug and tuning routines The communication is based on Modbus RTU the drive works as Modbus Slave and its register map...

Страница 7: ...Table Parameter Description Address Decimal Address Data Type Default Max PP_GAIN Position P Gain 0X0000 0 Signed 256 30000 PFF_GAIN Feed Forward Gain 0X0001 1 signed 50 30000 PD_GAIN Position D Gain...

Страница 8: ...ror Integral Gain in Current Control Loop C_TRIGGER Overload Current Trigger Level setting for LED Display FLT_TIME_CNST Input Pulse Train IIR filter Time Constant setting PFA_GAIN Input Acceleration...

Страница 9: ...STATE The state of the Motion Profile State Machine P_ERROR The Position Error between Commanded and Current Position Realtime C_POS The Current Encoder Position 16 bit Realtime C_Angle The Commutatio...

Страница 10: ...cond Data bits 8 Parity None Stop Bits 1 Motion Profiler Status 8196 Supported Functions 0 Motor Start Start Operation 03 Read Single Multiple Registers 1 Running Command Running Read Only 06 Write Si...

Страница 11: ...Motion SDA 0x06 0x20 0x02 Value 0xFFFF 8 Value 0xFF CRC16 SDA 0x06 0x20 0x03 Value 24 Value 0xFFFFFF 16 CRC16 Motion Status SDA 0x06 0x20 0x04 Value 8 Value 0xFF CRC16 Power Supply Selection The gener...

Страница 12: ...nstallation or handling Drive is not powering up no LED Check that the connectors to the drive are tightly plugged in Check the supply voltage is adequate and in correct polarity Drive might be damage...

Страница 13: ...er phase http www rhinomc com Page 13 Hybrid AC Driver RMCS 1120 Control Signal Connection NPN pull down In this connection technique all the signal ve inputs are connected to a common high voltage VC...

Страница 14: ...ol Signal Connection PNP pull up In this connection technique all the signal ve inputs are connected to a common low voltage GND The opto isolators LED is turned on by a pull up on the Ve terminals by...

Страница 15: ...p www rhinomc com Page 15 Hybrid AC Driver RMCS 1120 2 phase 4 lead Motors Connections 4 lead motors are the least flexible but easiest to wire Speed and torque will depend on winding inductance In se...

Страница 16: ...ilable here http rhinomc com downloads Hybrid_Servo_Tuner_Setup_Modbus exe The software is compatible with Windows XP and later operating systems including Windows 7 8 and 10 Both 32 bit and 64 bit ve...

Страница 17: ...RMCS 1120 Then it will show the install path and shortcut folder in start menu Click next and then finish on the next screen to finish the installation To start the software you can go to Start Menu...

Страница 18: ...al to RS485 converter as shown in image below D and D Lines needs to be connected between drive and converter After connecting and installing the driver you need to make sure that hardware or virtual...

Страница 19: ...ton for Available Slaves It will search from 1 to 247 slaves for response If it gets a response the slave will be added in drop down You can see the progress in status bar It will take a lot of time t...

Страница 20: ...drive to a file and load it when required On opening such saved file all the parameters will be written to the drive and drive will immediately start responding according to the new parameters In case...

Страница 21: ...Actual 32 bit position of encoder from startup or set position 3 Approximate speed in RPM 4 Exact angular positon of encoder in counts and degrees 5 Approximate current This data is also shown in grap...

Страница 22: ...the text box Speed will change immediately if you press button or enter when in textbox Speed will change even when motor is running Acceleration can be set same as speed This acceleration works only...

Страница 23: ...irection M100 M 100 M1000 M 1000 M4000 and M 4000 commands will work same as M but with fixed number of steps The RMCS 1120 drive supports absolute 32 bit positon output on modbus This means that the...

Страница 24: ...ve gone through this entire installation manual and datasheet before deciding that your product is liable for replacement or repair under this 6 month warranty Customer shall prepay shipping charges f...