3
ELECTRICAL INSTALLATION
This appliance should be connected to a hot water supply (Max 65°C ) for in accordance
with
Australian Standard AS/NZS 3500.1.
for optimum performance.
The water supply pressure should be a minimum 200 kPa at all times and flow rate should
be at least 10 litres per minute. A static pressure higher than 600 kPa (73.5 psi) requires a
pressure reducing valve upstream of the supply line. If water pressure is below 150 kPa,
the use of a rinse booster pump is recommended.
This appliance is designed to drain to a tundish. Waste connection to a spigot is not
recommended and may cause draining issues.
The drainpipe should withstand 70°C (158°F) in continuous duty conditions.
The grey water drain hose must have a fixed watertight seal above the tundish in
accordance with the Australian Standard AS/NZS 3500.2.
A DIAGRAM SHOWING THE CORRECT METHOD OF WASTE INSTALLATION IN ACCORDANCE
WITH THE AUSTRALIAN STANDARD AS/NZS 3500.2 IS BELOW
PLUMBING INSTALLATION
WMTS
-
101
WM-022203
This appliance is intended to be connected to a
15amp
electrical supply and
must be
earthed
.