- 24 -
Fault messages
In a Fault condition the fault display appears with the fault code. On unloading side the FAULT-
led turns red. By pressing
Info
the possible cause and recommended actions for the repair wil
be displayed. Service shall always be contacted and called for, if a Fault condition occurs.
By inserting the service code the chamber will be emptied automatically
to avoid danger of hot water.
The load must be reprocessed (the selected cycle must be run again)
always after incomplete cycle !
Nr
Fault message
Nr
Fault message
1
Loading door has opened during the cycle.
23
Water temperature below the set value
3
Controlling temperature sensor has short circuit.
4
Controlling temperature sensor has open circuit.
25
Loading door lock not interlocked
5
Verifying temperature sensor has short circuit.
26
Loading door stayed interlocked
6
Verifying temperature sensor has open circuit.
27
Door is not closed.
7
Water intake is blocked.
8
There is water in the chamber.
32
Loading door interlock opened during cycle
9
Water heating failed
33
Pressure transmitter has open circuit
10
Water circulation pressure too low.
34
Chemical flow 1 fault
11
Overflow, water level too high.
35
Chemical flow 2 fault
12
Water drained from chamber at wrong time.
13
Water temperature above set limit
38
Chemical tank 1 empty
14
Water circulation pressure dropped too low
39
Chemical tank 2 empty
16
Difference between temperature sensors
is too high
41
Rinse aid tank empty
21
Water pump thermal relay has been tripped
52
Electric board temperature too high
See appendix 1 for detailed instructions.
25
Содержание DEKO 25iX
Страница 2: ...2 ...
Страница 32: ...32 ...
Страница 34: ...34 ...
Страница 35: ...11 APPENDIX II USER INSTRUCTIONS USER INSTRUCTIONS 35 ...
Страница 36: ...36 ...