10.0 RECOMMENDED SPARE PARTS
The only parts that may need eventual
replacement is the rotor seal and the isolation
seal. Genuine Rheodyne rotor seals are
easily replaced by following the instructions
in Section 8.0.
Table I shows the Rheodyne part numbers
for the replacement rotor seal:
Table I.
Standard
L
Model
Models
Models
7000 and
7040
7010-039
7000-016
7030
7030-003
7030-014
7060
7060-070
7060-064
A convenient alternative to separate
replacement part ordering is the Rheodyne
RheBuild
®
Kit for Models 7010, 7000 and
7040. The RheBuild Kit includes all
necessary parts, tools, and instructions to
maintain the quality performance of your
Rheodyne valve.
7010-999
RheBuild Kit for 7010,
7000, and 7040.
11.0 WARRANTY
All Rheodyne products are warranted
against defects in materials and
workmanship for a period of one-year
following the date of shipment by Rheodyne.
Rheodyne will repair or replace any
Rheodyne product that fails during the
warranty period due to a defect in materials
or workmanship at no charge to the
customer. The product must be returned to
Rheodyne’s factory in original packaging or
equivalent, transportation prepaid. Damage
occurring in transit is not covered by the
warranty. This limited warranty is
Rheodyne’s sole warranty of its products,
and all other warranties of merchantability or
fitness for any particular purpose are hereby
disclaimed.
Under no circumstances will Rheodyne be
liable for any consequential or incidental
damages attributable to a claimed failure of a
Rheodyne product, even if Rheodyne has
been placed on notice of possibility of such
damages.
Detector
Column B
Position A
Column A
3
2
4
6
5
1
Sample Injector
Detector
Column B
Position B
Column A
3
2
4
6
5
1
Sample Injector
Fig. 7. Two column selection using Model 7000.
Detector A
2
1
3
5
4
6
Column
Position B
Sample
Injector
Pump A
1.00
Detector B
Position A
2
1
3
5
4
6
Column
Sample
Injector
Pump A
1.00
Detector A
Detector B
Fig. 9. Diverting flow from one detector to the
other using Model 7030.
Fig. 8. Illustration of column flow reversal for
backflushing using Model 7040.
Detector
Column
Column
Pump
3
4
6
5
1
Detector
Position A (Forward Flow)
Position B (Reverse Flow)
3
2
4
6
5
1
Sample Injector
1.00
Pump
2
Sample Injector
1.00
Fig. 10. Six column selection using two
Model 7060 switching valves.
Detector
3
2
4
6
7
5
1
3
2
4
6
5
1
1
2
3
4
5
6
Pump
Sample
Injector
1.00
1
Tefzel and Vespel are trademarks of E.I. DuPont.
Page 4 of 4
2320666B
6/02
Rheodyne LLC • A Unit of IDEX Corporation • 600 Park Court, Rohnert Park, CA 94928 • (707) 588-2000 • Fax (707) 588-2020
www.rheodyne.com