Installing the water heater.

This water heater must be installed in accordance with these instructions, local codes, utility company
requirements, and/or in the absence of local codes, use the latest edition of the American National
Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association,
1515 Wilson Blvd., Arlington, VA 22209 as booklet Z223.1 or National Fire Prevention Association,
Batterymarch Park, Quincy, MA 02269 as booklet NFPA No. 54.

Location

The water heater should not be located
in an area where leakage of the tank or
connections will result in damage to the
area adjacent to it or to lower floors of
the structure. 

When such areas cannot be avoided it is
recommended that a suitable catch pan,
adequately drained, must be installed
under the water heater.

The pan must not restrict combustion
air flow to the bottom of the water heater.

Catch pan kits are available from the store
where the water heater was purchased,
or any water heater distributor.

A gas fired water heater should not be
installed in a space where liquids which
give off flammable vapors are to be used
or stored. Such liquids include gasoline,
LP gas (butane and propane), paint or
adhesives and their thinners, solvents 
or removers.

Because of natural air movement in a
room or other enclosed space,
flammable vapors can be carried some
distance from where their liquids are
being used or stored. The open flame of
the water heater’s pilot light or main
burner can ignite these vapors causing
an explosion or fire which may result in
severe burns, death or property damage. 

For these reasons installation of a gas fired
water heater in a garage is not desirable.

Raising the gas fired water heater will
reduce, but not eliminate, the possibility
of lighting the vapor of any flammable
liquids which may be improperly stored
or accidentally spilled.

Stand kits to raise the water heater 18

above the floor are available from the store
where the water heater was purchased,
or any water heater distributor. These
kits must comply with local codes.

The water heater must be located so it is
not subject to physical damage, for example,
by moving vehicles, area flooding, etc. 

The water heater should be installed
as close as practical to the gas vent
or chimney. 

Long hot water lines should be insulated
to conserve water and energy. 

The water heater and water lines
should be protected from exposure 
to freezing temperatures.

Do not

install the water heater in

bathrooms, bedrooms, any occupied
rooms normally kept closed, or in
outdoor unprotected areas.

Minimum clearance from combustible
construction is 1

sides and rear; 3

from front of control; 12

from the

top. If the clearances stated on the
Instruction/Warning Label, located on
the front of the heater differ, install
the water heater according to the
clearances stated on the label.

The water heater may be installed on
combustible floors, but not directly on
carpeting. If the water heater must be
installed on carpeting, place a metal
or wood panel beneath the water
heater, extending beyond its full width
and depth at least 3

in all directions.

If the water heater is installed in an
alcove or closet, the entire floor must
be covered by a wood or metal panel. A
minimum of 24

clearance from the

front and top should be available for
adequate inspection and servicing.

WARNING: Combustible construction

refers to adjacent walls and ceilings
and should not be confused with
combustible or flammable products 
and materials. Combustible and/or
flammable products and materials
should never be stored in the vicinity 
of this or any gas appliance.

The auxiliary catch pan
installation MUST conform 
to local codes.

Max.

2

Diameter of

water heater

plus 2

min.

7

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

Troubleshooting Tips

Customer Service

WARNING: If a location 

in a garage is the only
alternative, the gas water
heater should be installed
so that the open flame of
the pilot and main burner
are no less than 18

above

the garage floor, unless
specifically exempted from
this by local code, rule,
regulation or custom. 

Содержание SG Series

Страница 1: ...ition System The purpose of this manual is twofold one for the installing contractor to provide requirements and recommendations for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance and trouble shooting of the water heater This manual includes a parts list It is imperative that all persons who...

Страница 2: ...he life of your water heater You ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips first you may not need to call for service at all READ THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original pu...

Страница 3: ...THE WATER HEATER Gasoline as well as other flammable materials and liquids adhesives solvents etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water heater Be sure to read and follow the warning label pictured below and other labels on the water heater as well as the warning...

Страница 4: ...r example in a basement if such installation is prohibited by federal state and or local laws rules regulations or customs Propane or LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Make sure to look and smell for LP gas leaks before attempting to light the appliance Use a soapy solution to check all gas fit...

Страница 5: ... at the left details the approximate water temperature for each mark on the Thermostat Temperature Dial DANGER There is a Hot Water SCALD Potential if the thermostat is set too high D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at...

Страница 6: ...ed to a qualified technician SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or loss of life FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heate...

Страница 7: ...he water heater was purchased or any water heater distributor These kits must comply with local codes The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater should be installed as close as practical to the gas vent or chimney Long hot water lines should be insulated to conserve water and energy The water heater and...

Страница 8: ...pecified above and each must have a minimum net free area of not less than one square inch per 4000 BTUH of the total input rating of all the appliances in the enclosure If horizontal ducts are used to communicate with the outdoors each opening must have a minimum net free area of not less than one square inch per 2000 BTUH of the total input rating of all the appliances in the enclosure If ducts ...

Страница 9: ...ter heater and the check valve see illustration below The expansion tank is designed with an air cushion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor water supplier or plumbing insp...

Страница 10: ... valve and must pitch downward from the valve to allow complete drainage by gravity of the relief valve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fill the Water Heater Make certain that drain valve is closed then open the...

Страница 11: ...g system during any high pressure testing of that system at pressures in excess of 1 2 psi 14 w c The water heater must be isolated from the gas piping system by closing the manual gas shut off valve during any pressure testing of the gas supply piping Gas Supply The branch gas supply line to the water heater should be clean 1 2 black steel pipe or other approved gas piping material A ground joint...

Страница 12: ...er disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices CAUTION Application of any external insulation to this water heater will require careful attention to the following Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket Do not apply insulation to the top o...

Страница 13: ... drinking water system Toxic chemicals such as those used for boiler treatment may be present and will contaminate the drinking water supply causing possible health risks Never introduce toxic chemicals such as those used for boiler treatment into this system Tee fitting for horizontal hot water supply lines Hot water supply to house From HOT outlet on water heater From HOT outlet on water heater ...

Страница 14: ...and any gas valve that has been under water FOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life 1 STOP READ THE SAFETY INFORMATION ABOVE ON THIS LABEL 2 TURN GAS COCK KNOB CLOCKWISE TO OFF POSITION 3 TURN TEMPERATURE DI...

Страница 15: ...tructions exactly a fire or explosion may result causing property damage personal injury or loss of life 1 STOP READ THE SAFETY INFORMATION ABOVE ON THIS LABEL 2 TURN THE GAS COCK KNOB CLOCKWISE TO OFF POSITION 3 TURN THE TEMPERATURE DIAL COUNTERCLOCKWISE TO LOWEST SETTING 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS IF YOU SMELL GAS STOP FOLLOW B IN THE SAFETY INFORMATION ABOVE ON THIS LABEL IF YOU...

Страница 16: ...local plumbing authority for further information The chart below may be used as a guide in determining the proper water temperature for your home Safety Precautions Do turn off manual gas shut off valve if water heater has been subjected to over heating fire flood physical damage or if the gas supply fails to shut off Do Not turn on water heater unless it is filled with water Do Not turn on water ...

Страница 17: ...burner if the pilot flame is extinguished for any reason The thermostat is also equipped with a single use gas shut off device that will shut off the gas supply to the burner if the water heater exceeds normal operating temperatures Refer to the BEFORE YOU CALL FOR SERVICE section of this manual or contact your dealer WARNING Should overheating occur or the gas supply fail to shut off turn off the...

Страница 18: ...pen drain NOTE If the temperature and pressure relief valve on the hot water heater discharges periodically this may be due to thermal expansion in a closed water system Contact the water supplier or your plumbing contractor on how to correct this Do not plug the relief valve outlet A water heater s tank can act as a setting basin for solids suspended in the water It is therefore not uncommon for ...

Страница 19: ...r can also be cleaned by scrubbing with mild detergent CAUTION For your safety cleaning of the main burner should be performed only by qualified service personnel Proper burner and pilot flame pattern Vacation and Extended Shut Down If the water heater is to remain idle for an extended period of time the power and water to the appliance should be turned off to conserve energy and prevent a build u...

Страница 20: ...lation Air information in the Locating the water heater section of this manual Unable to light Temperature dial not See the Lighting the water heater section of this the pilot correctly positioned manual Pilot orifice clogged The pilot should be cleaned or replaced by a qualified service technician Pilot tube pinched or The pilot should be cleaned repaired or replaced by a clogged qualified servic...

Страница 21: ...ave Wait for the water heater to recover after an abnormal no hot water exceeded the capacity demand of the water heater Low gas pressure Check gas supply pressure and manifold pressure The pilot may be out Check the pilot If necessary relight using the instructions in the Lighting the water heater section of this manual The thermostat may See the Temperature regulation of the water heater be set ...

Страница 22: ... plate Part description as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of gas piping thermostat burners vent connectors or other safety devices Refer repairs to qualified service personnel Draft hood Temperature and pressure relief valve Drain valve shroud Burner supply tube Inner door Flue baffle hanger Anode rod Dip tube Dip tube gasket Pilot supply tube...

Страница 23: ...23 Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here ...

Страница 24: ...r Serial Number Important Mail Today First Name Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing the registration below store this document in a safe place It contains information you will need should you require service Read your Owner s Manual caref...

Отзывы: