Exiting Lock-Out Mode:
To exit the lock-out mode, remove 24 volts to the defrost
control by removing power to indoor air-handler/furnace or by shorting the two
defrost control test pins together.
ENHANCED FEATURE DEFROST CONTROL DIAGNOSTIC CODES
REPLACEMENT PARTS
Contact your local distributor for a complete parts list.
CHARGE INFORMATION
Refer to the appropriate charge chart included in this manual.
TROUBLESHOOTING
Refer to the troubleshooting chart included in this manual.
WIRING DIAGRAMS
Refer to the appropriate wiring diagram included in this manual.
LED 1
LED 2
Control Board Status
OFF
OFF
No Power
ON
ON
Coil Sensor Failure
OFF
ON
Ambient Sensor Failure
FLASH
FLASH
Normal
OFF
FLASH
Low Pressure Lockout (short test pins to reset)
FLASH
OFF
High Pressure Lockout (short test pins to reset)
ON
FLASH
Low Pressure Control Open
FLASH
ON
High Pressure Control Open
Alternate Flashing
5 Minute Time Delay
Содержание RJNL-A036CK
Страница 67: ...67 FIGURE 19 WIRING DIAGRAM...
Страница 68: ...68 FIGURE 20 WIRING DIAGRAM...
Страница 69: ...69 FIGURE 21 WIRING DIAGRAM...
Страница 70: ...70 FIGURE 22 WIRING DIAGRAM...
Страница 71: ...71 FIGURE 23 WIRING DIAGRAM...
Страница 72: ...72 FIGURE 24 WIRING DIAGRAM...
Страница 73: ...73 FIGURE 25 WIRING DIAGRAM...
Страница 74: ...74 FIGURE 26 WIRING DIAGRAM...
Страница 75: ...75 FIGURE 27 WIRING DIAGRAM...
Страница 76: ...76 FIGURE 28 WIRING DIAGRAM...
Страница 77: ...77...
Страница 78: ...78...
Страница 79: ...79...
Страница 80: ...80 5 TON 13 SEER...
Страница 81: ...81 5 TON 14 SEER...
Страница 84: ...84 CM 0710...