Rheem Heating, Cooling and Water Heating 3
8
SELECTION PROCEDURE
(WITH EXAMPLE)
I. Define hot water load for the total
required domestic hot water
usage.
As an example, let’s assume that the
selected Tankless Water Heater for your
whole house solution is the RTG-74 and
your calculated heat gain and heat loss
values are as stated in section II.
II. Determine cooling and heating
requirements at design conditions:
The ACCA’s Manual J Residential Load
Calculation method is the established
trade standard, approved by ANSI, for
the correct siziing and selection of
Heating, Ventilation, Air-Conditioning
and Refrigeration (HVACR) equipment in
residential homes. The most recent
revision is the eight edition, an all-
inclusive new approach to ensuring that
Indoor Air Quality (IAQ) systems are as
efficient, safe, and healthy as possible.
Refer to the Air Conditioning Contractors
of America website at:
http://www.acca.org/tech/manualj/ or a
qualified HVACR contractor for further
assistance.
Assumptions:
Required Cooling Capacity . 48,000 BTU/HR
(Total Capacity)
Required Heating Capacity . 60,000 BTU/HR
Evaporator Air Quantity. . . . . . . . . 1600 CFM
External Static Pressure . . . . . . . 0.2 in. W.C.
Electrical Characteristics . . . . . . . . . 115-1-60
III. Determine total external static
pressure (ESP) at design
conditions:
Before using the Airflow Performance
Table calculate the total static pressure
required. From the given example, note
the Wet Coil Pressure Drop (selected
from the field supplied Evaporative
Cased Coil Installation Instructions), and
the Filter Pressure Drop. Determine both
static pressures at 1600 CFM:
Wet Coil Pressure Drop. . . . .30 in. W.C.
(From Coil Manufacturer’s Installation Instructions)
External Static Pressure . . . 0.2 in. W.C.
(Ductwork, etc.)
Filter Pressure Drop
0.8 in. W.C.
(0.8 inches if the included filter is used; refer to
the filter’s manufacturer’s instructions if another
filter is used.)
Total Static Pressure
0.58 in. W.C.
IV. Select unit based on required
cooling capacity airflow:
For an initial selection, choose a unit
size that will provide the required
airflow. Refer to Airflow Performance
Table. Note that at 0.6 ESP (external
static pressure) the RHWB-
06WMP48A unit will deliver 1560
CFM when configured for HIGH
speed.
V. Select heating capacity of unit
to provide the requisite design
condition:
From the Hydronic Air Handler/
Tankless Water Heater, note that the
unit RHWB-06WMP48A, (as selected
above) when matched with the RTG-
95 Tankless Water Heater, will
provide 59.2 MBH (59,200 BTU/HR)
at an input water temperature (to Air
Handler) of 150°F.
Model Number Nomenclature
RHWB 06W M P 36
A
Rheem
Air Handler
Water
Denotes a major design change in the
product line (i.e. capacity)
Nominal Heating Capacity (BTU/HR)
06W 60,000
08W 80,000
10W 100,000
Revision
A = Rev 0
Blower Size
M = 11x7
R = 11x10
Variations
P = PSC Motor
48 = 15-1700 CFM
60 = 1900-2100 CFM
Design Series
R
Brand
Application
Type
Design
Series
Heating Output Designation
Blower
Size
Variations
Heat/Cool
Designation
Revision
Inlet Water
Temp = 150F
Output
BTU/HR
H
W
B
-0
6
W
M
P
36
A
R = Rheem H = Air handler
W = Water B = 2nd Series
06W
60,000
M = 11x7
P = PSC
48 = 1500-1700 CFM
A = Rev 0
08W
80,000
R = 11x10
60 = 1900-2100 CFM
10W
90,000
HYDRONIC AIR HANDLER PHYSICAL DATA AND SPECIFICATIONS
U.S. and Canadian Models
IMPORTANT: BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY
INFORMATION AVAILABLE FROM YOUR RETAILER.
HYDRONIC AIR HANDLER MODEL IDENTIFICATION
MODEL NUMBERS
RHWB-06WMP48A
RHWB-08WRP60A
RHWB-10WRP60A
NOMINAL HEATING CAPACITY RANGE (BTUH)
32,000 to 72,000
35,000 to 82,000
35,000 to 90,000
BLOWER (D x W) [mm]
11 x 7
[279 x 178]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
MOTOR HP [W] - SPEEDS - TYPE
3
/
4
[559] - 4 - PSC
3
/
4
[559] - 4 - PSC
3
/
4
[559] - 4 - PSC
HEATING SPEED
Med Low
Med High
High
MOTOR FULL LOAD AMPS
9.5
9.5
9.5
HEAT EXT. STATIC PRESSURE (IN.W.C.) [kPa]
0.8 [.20]
0.8 [.20]
0.8 [.20]
HEATING CFM @ .8" [.199 kPa] W.C. ESP [L/s]
1000 [471]
1453 [685]
1818 [858]
RATED EXT. STATIC PRESSURE (IN.W.C.) [kPa]
0.5 [.12]
0.5 [.12]
0.5 [.12]
COOLING SPEED
High
High
High
TEMPERATURE RISE RANGE °F [°C]
40-70
[22.2-38.9]
35-65
[19.4-36.1]
35-65
[19.4-36.1]
STANDARD, HIGH VELOCITY
PERMANENT FILTER (IN.)
15
3
/
4
x 25 x 1
22
3
/
4
x 25 x 1
22
3
/
4
x 25 x 1
RETURN AIR CABINETS (OPT.)
RXGR-
FILTER SIZE
[mm]
C17B
(2) 12" x 16"
[305 x 406]
C24B
(2) 24" x 16"
[609 x 406]
C24B
(2) 24" x 16"
[609 x 406]
COOLING CFM @ .5" [.124 kPa] W.C. ESP [L/s]
1622 [765]
1871 [883]
1973 [931]
APPROX. SHIPPING WEIGHT (LBS) [kg]
118 [53.5]
137 [62.1]
145 [65.7]
Содержание RHWB series