background image

Air

Standard & Optional Equipment

RGPS Series

3

WARNING

THIS FURNACE IS NOT APPROVED

OR RECOMMENDED

FOR USE IN MOBILE HOMES

DIRECT SPARK IGNITOR

IN-SHOT BURNERS

DRAFT INDUCER MOTOR

PATENTED HEAT EXCHANGER

INTEGRATED

FURNACE

CONTROL

STANDARD EQUIPMENT

Completely assembled and wired; induced draft; pressure switch;
redundant main gas control; blower compartment door safety switch;
solid state time on/time off blower control; limit control; manual shut-
off valve, pressure regulator for natural and L.P. (propane) gas;
transformer; direct drive multi-speed blower motor. Furnaces are
equipped with cooling/heating relay and transformer (40VA) ready for
air conditioning applications. (Please note: a thermostat is not
included as standard equipment.) Flame sensor diagnostics.

OPTIONAL EQUIPMENT

Twinning Kit

Side and bottom filter frame assembly. Return air cabinet for all sizes.

NOTE: Furnace is not listed for use with fuels other than natural or L.P. 

(propane) gas.

The complete terms of limited and other warranties are available at our
sales office, or through local installer.

All models can be converted by a qualified Rheem distributor or local
service dealer to use L.P. (propane) gas without changing burners.
Factory approved kits must be used to convert from natural to L.P.
(propane) gas and may be ordered as optional accessories from a
Rheem parts distributor.

For L.P. (propane) operation, refer to Conversion Kit Index Form.

NOTE: For natural and L.P. (propane) gas models, standard hot surface
ignition is 100% safety lockout type.

Содержание RGPS series

Страница 1: ...andle and leaves room for optional equipment Convertible from upflow to horizontal left or right without field conversion Left or right side gas and electric inlet connections allow quick and simple c...

Страница 2: ...s RGPS Series 2 TABLE OF CONTENTS Standard Optional Equipment 3 Model Features Physical Data Specifications 4 Model Number Identification 5 Dimensional Data 6 7 Blower Performance Data 8 Accessories 9...

Страница 3: ...ng applications Please note a thermostat is not included as standard equipment Flame sensor diagnostics OPTIONAL EQUIPMENT Twinning Kit Side and bottom filter frame assembly Return air cabinet for all...

Страница 4: ...mm 153 4 x 25 400 x 635 153 4 x 25 400 x 635 153 4 x 25 400 x 635 153 4 x 25 400 x 635 191 4 x 25 489 x 635 191 4 x 25 489 x 635 223 4 x 25 578 x 635 223 4 x 25 578 x 635 Return Air Cabinets Opt RXGR...

Страница 5: ...05E 07E 10E 12E 15E Input BTU HR kW 50 000 15 75 000 22 100 000 28 125 000 37 150 000 44 P P Upflow Horizontal Multi Positional Tier III Electric Ignition NOx 05N 07N 10N 12N 15N M Blower Designation...

Страница 6: ...6 152 10EA 171 2 445 1611 32 415 123 8 314 151 2 381 0 3 76 0 1 25 3 76 6 152 115 52 2 120 54 4 15 241 2 622 2311 32 593 157 8 403 221 2 559 0 0 0 1 25 3 76 6 152 12 241 2 622 2311 32 593 157 8 403 2...

Страница 7: ...s 7 Horizontal Application Dimensional Data Horizontal Model MODEL RGPS A B C D E REDUCED CLEARANCE IN mm 07 171 2 445 1611 32 415 123 8 314 151 2 381 0 3 76 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BAC...

Страница 8: ...ED HIGH 1245 588 1555 734 1810 854 1220 576 1515 715 1755 828 1195 564 1475 696 1705 805 1165 550 1435 677 1645 776 1135 536 1395 658 1585 748 1105 522 1350 637 1530 722 1065 503 1300 614 1470 694 10E...

Страница 9: ...CODE FOR HIGH ALTITUDE U S Canada None required for high altitudes HIGH ALTITUDE CONVERSION KITS U S Canada None required for high altitudes 80 HIGH ALTITUDE INSTRUCTIONS CAUTION Always follow Nationa...

Страница 10: ...thin the applicable period stated in accordance with the terms of the limited warranty For complete details of the Limited and Conditional Warranties including applicable terms and conditions contact...

Страница 11: ...Air Notes RGPS Series 11...

Страница 12: ...ith Arkansas 72917 www rheem com In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 10 13 QG FORM NO G11...

Отзывы: