Replacing Diffuser, Impeller and Seal

A

DANGER: 

ELECTROCUTION 

OR ELECTRICAL SHOCK RISK. 

DISCONNECT ELECTRICITY BEFORE 

WORKING ON PUMP, OR SHOCK, BURN 

OR ELECTROCUTION CAN RESULT.

Remove power from the pump by turning off the breaker. 

Death or serious injury to service people, pool users or 

others due to electric shock could result from failure to 

avoid the high danger risk.

1.  Power  must  be  in  the  OFF  position  in  the  breaker 

panel as the unit is hard-wired directly into the power 

panel, meaning that is the only way to cut power.

2.  Allow the pump motor to cool down before servicing 

the unit.

3.  Close  the  water  valves,  if  installed,  to  isolate  the 

pump from the system. 

4.  Separate pump motor and flange from pump volute 

by  removing  the  two  outer  bolts  and  then  the  two 

outer bolts on the opposing side. Pull the motor and 

flange back and away from the volute. See 

Figure 1

.

Figure 1.  Pump Separation, Bolt Location

5.  Using a Phillips screwdriver, remove the three screws 

holding the diffuser to the flange/seal plate, freeing 

the diffuser for removal. See 

Figure 2

.

Figure 2. 

Diffuser Plate Separation, Screw Location

6.  Remove the impeller center screw using a 5/8 inch 

socket  wrench.    NOTE  –  this  screw  is  REVERSE 

THREADED  and  can  only  be  removed  by  turning 

CLOCKWISE  while  holding  the  impeller  stationary. 

See 

Figure 3

.

Figure 3.  Impeller Bolt Removal

7.  Removing  the  impeller  requires  holding  the  motor 

shaft  stationary  while  turning  the  impeller  counter-

clockwise. A flat screwdriver must be inserted into the 

slot in the end of the shaft at the rear of the motor. 

An access hole is provided in the center of the rear 

motor  cover.  While  holding  the  shaft  still  with  the 

screwdriver,  manually  rotate  the  impeller  counter-

clockwise to unscrew. See 

Figure 4

.

Figure 4.  Screwdriver Insertion Point

8.  Remove the remaining four bolts holding the flange/

seal plate to the motor, and separate the two. See 

Figure 5

.