INSTALLATION – WATER HEATER
18
DIMENSIONS AND TECHNICAL DATA
A G
D
B
HOT WATER
OUTLET
GAS INLET
(FLUSH TO BASE)
COLD WATER
INLET
69 K
HOT WATER
OUTLET
GAS INLET
120
120
69
COLD WATER
INLET
222
285
268
250
H
M
L
DIMENSIONS DIAGRAM
MECHANICAL INSTANTANEOUS
843 SERIES
R3.5
R8
120
120
D
E
(12L ONLY)
5
Model
834 012
834 016
Rated delivery
(@ 40°C rise)
litres / min
7.3
9.8
Recovery
(@ 25°C rise)
litres / min
12
16
Mass
Empty (unpackaged)
kg
21
25
Dimensions
A
B
D
E
G
H
K
L
M
834 012
mm
840
388
45
45
830
465
55
70
70
834 016
mm
875
443
50
50
866
451
48
84
84
Gas
Details
Hourly Gas
Consumption
(MJ)
Minimum
Gas
Pressure
(kPa)
Test Point Gas Pressure (kPa) Maximum
Gas
Pressure
(kPa)
Injector Size
(mm)
Pilot
Injector
(mm)
minimum
maximum
Size
012
016
012, 016
012
016
012
016
012, 016
012
016
012, 016
Natural
99
128
1.13
0.080
0.088
0.72
0.74
3.50
14 x
1.30 18 x
1.30
0.60
Propane
96
125
2.75
0.210
0.210
1.85
1.85
3.50
14 x
0.80 18 x
0.80
0.35
Model numbers: N = Natural, P = Propane, to denote gas type.
Letter N or P is included in the model number, e.g. 834016N0.
Character following gas type letter, 0 = no frost protection.
Technical data is subject to change.