Rheem Prestige RGFE-09EZCMS Скачать руководство пользователя страница 11

11

FIGURE 12

DOWNFLOW CONNECTION

A112001.S01

REFER TO INSTALLATION
MANUAL

FIGURE 11

UPFLOW CONDENSATE DRAIN

A112001.S01

REFER TO
INSTALLATION
MANUAL.

Содержание Prestige RGFE-09EZCMS

Страница 1: ...from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department Do not rely on smell alone to detect leaks Due to various factors you m...

Страница 2: ...STRUCTURE WHERE DAM AGE TO THE BUILDING OR BUILD ING CONTENTS MAY OCCUR AS A RESULT OF AN OVERFLOW OF THE COIL DRAIN PAN OR A STOP PAGE IN THE PRIMARY CONDEN SATE DRAIN PIPING SEE ACCES SORIES SECTION...

Страница 3: ...Edition National Electrical Code NFPA90A Installation of Air Conditioning and Ventilating Systems NFPA90B Installation of warm air heating and air conditioning systems The equipment has been evaluated...

Страница 4: ...The furnace controller will optimize furnace performance by monitoring all thermostat and temperature inputs and insuring the stable operation of the inducer gas valve and indoor blower motor ECM Var...

Страница 5: ...LOWER MOTOR 8 DOOR SWITCH 9 JUNCTION BOX 10 COMBUSTION AIR INLET 11 HALC 12 TOP PLATE 13 VENT CAP PLUG ITEM NO PART NAME 14 OUTLET AIR PIPE 15 INTEGRATED FURNACE CONTROL 16 TRANSFORMER 17 INDUCED DRAF...

Страница 6: ...ing insulation Some materials may be combustible Any additions changes or conver sions required in order for the furnace to satisfactorily meet the application needs should be made by a qualified inst...

Страница 7: ...dence Deterioration of the venting system or soot build up can cause leaks into the system Have a qualified installer service agency or the gas supplier replace damaged parts or repair obstructions in...

Страница 8: ...trodes The main solenoid on the gas valve is energized allowing gas to flow to the burners When flame is proven the ignition con trol is de energized 8 second maxi mum trial time The gas valve maintai...

Страница 9: ...the motor exterior And as suggested elsewhere in these instructions keep the air filters clean because dirty filters can restrict airflow and the motor depends on sufficient air flowing across and th...

Страница 10: ...e condensate tube to make sure condensate flows freely while the furnace is in operation IMPORTANT IT IS RECOMMENDED THAT AT THE BEGINNING OF THE HEATING SEASON THE CONDENSATE TRAP BE INSPECTED BY A Q...

Страница 11: ...11 FIGURE 12 DOWNFLOW CONNECTION A112001 S01 REFER TO INSTALLATION MANUAL FIGURE 11 UPFLOW CONDENSATE DRAIN A112001 S01 REFER TO INSTALLATION MANUAL...

Страница 12: ...12 CM 0710 FIGURE 13 HORIZONTAL CONDENSATE DRAIN...

Отзывы: