SOLAR COLLECTOR LOCATION
7
The installation of these solar collectors on a suitable cyclone frame, subject
to the frame‟s design criteria not being exceeded:
is suitable for installation in geographic locations within Wind Regions C
and D as defined in the Building Code of Australia, Australian / New
Zealand Standard AS/NZS 1170.2:2002 and the Australian Standard
AS 4055-2006, and
also provides an acceptable method of installation where it is necessary
to satisfy the requirements of the Building Code of Australia and
AS/NZS 3500.4 Clause 6.5.3.4 for high wind areas.
The collector kit is suitable for installations with an inclination of up to 45°.
Where the solar collectors are installed at inclinations greater than 45°, a
With Pitch frame is necessary. Refer to your local Solar Distributor for
details.
The installer must ensure the structural integrity of the building is not
compromised by the solar water heater installation and the roof structure is
suitable to carry the full weight of the solar collectors. If in doubt the roof
structure should be suitably strengthened. Consult a structural engineer.
Each solar collector and its fittings weighs approximately 40 kg when full of
water.
Refer to the installation instructions supplied with the solar storage tank for
details on the installation of the solar storage tank.
Roof area required for solar collectors:
2 solar collectors
– 2.3 m wide x 2.0 m deep. Weight (full) 80 kg approx.
LATITUDE OF SOME AUSTRALIAN CITIES
Adelaide
35°S Cairns
17°S Hobart
42°S Port Hedland 20°S
Alice Springs 24°S Canberra
35°S Mildura
34°S Rockhampton 24°S
Brisbane
27°S Darwin
12°S Melbourne
38°S Sydney
34°S
Broken Hill
31°S Geraldton
28°S Perth
32°S Townsville
19°S