Rheem HC-TST402DFMS Series Скачать руководство пользователя страница 8

The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required.
1. Humidifiers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced.
2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be serviced or replaced.
3. UV Lights = A programmable run time in days to indicate on the LCD when the Ultra-Violet Bulb will need to be replaced.
4. Service Timer = A programmable run time in days to indicate on the LCD when to call your service contractor.

To enter the Service Button Menu when no service reminders are on the display, press and release the SERVICE button. Press

TIME 

FWD

 to step through the menu items. To turn a menu item OFF or ON when selected, press 

 or 

. If you are

setting an item to ON, you can then use 

 or 

 to select the time interval. Press 

 

RUN

 to exit the menu and return to

normal operation.

When a service reminder appears on the display, press the SERVICE button to remove it and reset the timer to begin the count
down to the next service interval.

SERVICE REMINDER

8

1

Step

  Press Button(s)

Displayed

Press          or          to select:           

COMMENTS

 (Factory Default)

PAD TIME

(OFF) Hrs 

or 

REM PAD TIME

No. of Hrs

(ON) 

or 

(OFF)

Set Humidifier Maintenance Reminder. 

SERVICE

3

FLTR TIME

(OFF) /Hrs

or

REM FLTR TIME

No. of Hrs

(ON) 

or 

(OFF)

Set Air Filter Maintenance Reminder.

TIME

FWD

Service Button Menu

Returns to Normal Operation.

PRGM

RUN

2

SET PAD TIME

(100) Hrs

25 to 1975

Selects time intervals in increments of 25 hours. The RUN 
time accumulates when the HM terminal  is energized.

TIME

FWD

(If PAD TIME is ON)

4

SET FLTR TIME

(200) Hrs

25 to 1975

Selects time intervals in increments of 25 hours. 
The RUN time accumulates when the fan is operating.

TIME

FWD

(If FLTR TIME is ON)

5

UV TIME

(OFF) Days

or

REM UV TIME

No. of Days

(ON) 

or 

(OFF)

Selects UV Light Maintenance Reminder.

TIME

FWD

6

SET UV TIME

(375) Days

25 to 1975

Selects time intervals in increments of 25 days. The RUN 
time is the calendar time from when it is entered or reset.

TIME

FWD

(If UV TIME is ON)

7

SERV TIME

(OFF) Days

or

REM SERV TIME

No. of Days

(ON) 

or 

(OFF)

Selects Routine Maintenance Service Call Reminder.

TIME

FWD

8

SET SERV TIME

(175) Days

25 to 1975

Selects time intervals in increments of 25 days. The RUN 
time is the calendar time from when it is entered or reset.

TIME

FWD

(If SERV TIME is ON)

Содержание HC-TST402DFMS Series

Страница 1: ...orrect wiring will damage thermostat and could cause personal injury and or property damage Do not use on circuits exceeding specified voltage Higher voltage will damage thermostat and could cause sho...

Страница 2: ...from the old thermostat one at a time DO NOT let the wires fall back into the wall Install the new thermostat using the follow ing procedures ATTACH BASE TO WALL Remove packing material from the ther...

Страница 3: ...r wiring see CONFIGURATION section for proper thermostat configuration THERMOSTAT TERMINALS Upper L SA SB SC OT Malfunction Light Remote Sense A Remote Sense B Remote Sense C Outdoor Sensor THERMOSTAT...

Страница 4: ...OMPRESSOR SYSTEM ONLY If you have a single stage compressor system see the diagram below A relay customer provided should be installed as shown in Fig 5 to switch the fan speed to the next lower speed...

Страница 5: ...6 step 6 is for heat pump only These items allow the cycle times in heating cooling and auxiliary heat pump systems only to be increased or decreased The factory set values can be adjusted higher for...

Страница 6: ...T COOL and AUTO with SYSTEM button EMER appears in sequence after HEAT if HEAT PUMP is selected Program RUN TIME FWD Heat Pump ONLY TIME FWD TIME FWD TIME FWD TIME FWD TIME FWD TIME FWD TIME FWD 6 SET...

Страница 7: ...e slightly warmer and more comfortable Example If you want the blower to go to a lower speed when the system is running greater than 50 of the time then reduce the Blower Balance Point to 50 To turn t...

Страница 8: ...service interval SERVICE REMINDER 8 1 Step Press Button s Displayed Press or to select COMMENTS Factory Default PAD TIME OFF Hrs or REM PAD TIME No of Hrs ON or OFF Set Humidifier Maintenance Reminde...

Страница 9: ...temperature to call for heat 3 LED indicatior will glow red indicat ing the thermostat is calling for heat 4 Lower the termperature a few degrees below room temperature and the red LED and the heat sh...

Страница 10: ...re securely attached 3 Cooling system requires service or Same procedure as diagnostic for No Heat thermostat requires replacement condition except press the SYSTEM button until COOL is displayed and...

Страница 11: ...e it will provide precise temperature control on a properly sized system Any time your program is running and you would like to override it for a specific amount of time press or until the temperature...

Страница 12: ...357 367 H O M E O H O M E O H O M E O H O M E O H O M E OWNER HELP LINE WNER HELP LINE WNER HELP LINE WNER HELP LINE WNER HELP LINE 1 800 284 2925 1 800 284 2925 1 800 284 2925 1 800 284 2925 1 800 28...