6
Rheem Heating, Cooling and Water Heating
RXPF-F01 and F02
FOSSIL FUEL KIT
—is for use with Rheem Heat Pumps and Classic
Series warm air furnaces. RXPF-F02 meets TVA requirements.
ACCESSORIES—DOWNFLOW
DOWNFLOW WARNING: Unit design is certified for installation on non-com-
bustible floor. A special factory supplied combustible floor sub-base is
required when installing on a combustible floor. Failure to install the sub-base
may result in fire, property damage and personal injury.
COMBUSTIBLE
FLOOR BASE
A
IN. [mm]
B
IN. [mm]
USE WITH
FURNACE SIZES
RXGC-B24
25
[635] 23
3
/
4
[603]
RGLQ-12, RGLQ-15
RXGC-B14
14
1
/
2
[368] 13
1
/
4
[337]
RGLQ-05
RXGC-B17
18
[457] 16
3
/
4
[425]
RGLQ-07, RGLQ-10(-)A
RXGC-B21
21
1
/
2
[546] 20
1
/
4
[514]
RGLQ-10(-)B
C
IN. [mm]
21
3
/
4
[552]
11
1
/
4
[286]
14
3
/
4
[451]
18
1
/
4
[464]
FOR HIGH ALTITUDES:
HIGH ALTITUDE CONVERSION:
See Installation Instructions for more high altitude information.
CAUTION:
Always follow National Fuel Gas Code (NFGC) guidelines
when converting furnaces for high altitudes.
COMBUSTIBLE FLOOR BASE DIMENSIONS
RXGF-CC*
FILTER RACK
—Downflow top
return mount.
NOTE:
Filter racks are shipped
without filters.
*Filters available through PROSTOCK
®
.
14
1
/
2
[356]
45 [13.19] & 50 [14.65]
14 [356] x 20 [508]
1
17
1
/
2
[445]
67 [19.64], 75 [21.98] & 100 [29.31]
12 [305] x 20 [508]
1
21
1
/
2
[533]
100 [29.31]
12 [305] x 20 [508]
2
24
1
/
2
[622]
125 [36.63] & 150 [44.0]
14 [356] x 20 [508]
2
DOWNFLOW FILTER SIZES
FURNACE
WIDTH
IN. [mm]
INPUT
BTUH [kW]
SIZE
IN. [mm]
QUANTITY
[
] Designates Metric Conversions