Active Protection – Code L4 – Locked rotor
If the ICC detects the compressor has run less than 15 seconds before the pro-
tector tripped for four (4) consecutive starts during the same command for unit
operation, the ICC will lockout the compressor to keep it from continuing to oper-
ate and flash a “L” on the dual 7-segment LEDs followed by a “04”.
IIM
MPPO
ORRTTAANNTT:: This mode of active protection must be manually reset.
44)) CCoom
mpprreessssoorr PPrrootteeccttoorr TTrriipp
• If ICC detects a protector trip it will display a “P”. If protector doesn’t reset within 4
hours, the ICC display will change to “5”.
Compressor Protector – Code P – Protector Trip
55)) O
Oppeenn SSttaarrtt CCiirrccuuiitt LLoocckkoouutt
• The ICC will display a flashing “L” followed by a flashing “06” when an open start
circuit condition occurs.
Active Protection – Code L6 – Compressor open start circuit
If the ICC lockouts L6 and L7 detect current in the run circuit without current pre-
sent in the start circuit, the ICC will lockout the compressor to keep it from contin-
uing to operate and flash a “L” on the dual 7-segment LEDs followed by a “06”.
IIM
MPPO
ORRTTAANNTT:: This mode of active protection must be manually reset.
66)) O
Oppeenn RRuunn CCiirrccuuiitt LLoocckkoouutt
• The ICC will display a flashing “L” followed by a flashing “07” when an open start
circuit condition occurs.
Active Protection – Code L7 – Compressor open run circuit
If the ICC detects current in the start circuit without current present in the run cir-
cuit, , the ICC will lockout the compressor to keep it from continuing to operate
and flash a “L” on the dual 7-segment LEDs followed by a “07”.
23
C
O
M
F
O
R
T
C
O
N
T
R
O
L
2
S
Y
S
T
E
M
™
C
O
N
T
R
O
L
W
IR
IN
G
L
0 4
L
0 6
L
0 7
P
Содержание ASL-JEC 18 Seer
Страница 31: ...50 FIGURE 14 WIRING DIAGRAM FOR ASL 039JEC 048JEC 060JEC DUAL DRIVE...
Страница 32: ...51...
Страница 33: ...CM 0610 52...