HOW TO OBTAIN SERVICE ASSISTANCE

Should you have any questions about your new water heater, or if 
it requires adjustment, or routine maintenance, it is suggested that 
you first contact your installer, plumbing contractor or previously 
agreed upon service agency. In the event that the firm has moved, 
or  is  unavailable,  refer  to  the  telephone  directory  commercial 
listings or local utility for qualified service assistance.

Should your problem not be resolved to your complete satisfaction, 
you  should  then  contact  the  Manufacturer’s  National  Service 
Department at the following address:

In the United States:

RHEEM MANUFACTURING COMPANY 
1241 Carwood Ct. 
Montgomery, AL 36117

In Canada:

Rheem Canada Ltd 
125 Edgeware Road, Unit 1 
Bramptom, ON 
L6Y 0P5

You may also obain technical assistance by calling 
1-800-432-8373.

When contacting the manufacturer, the following information should 
be made available:

1. Model and serial number of the water heater as shown on the 
rating plate attached to the jacket of the water heater.
2. Address where the water heater is located and can be seen.
3. Name and address of installer and any service agency who per-
formed service on the water heater.
4. Date of original installation and dates any service work was per-
formed.
5. Details of the problems as you can best describe them.
6. List of people, with dates, who have been contacted regarding 
your problem.

Содержание AdvantagePlus HE119-130LP

Страница 1: ...ntil authorized by the gas supplier or re department Improperinstallation adjustment alteration service or maintenance can cause injury property damage or death Refer to this manual Installation and s...

Страница 2: ...1 1848 HE80 130 80 303 160 71 C 130 000 100 F GAL 68 81 93 106 131 168 206 355 505 32 33 7 C LTR 259 306 354 401 495 637 779 1345 1912 HE119 130 119 450 160 71 C 130 000 100 F GAL 96 108 121 133 158 1...

Страница 3: ...Exhaust Vent And Intake Air Vent Pipe Location 11 13 D Exhaust Vent And Intake Air Vent Sizing 14 E Longer Vent Runs 14 F Exhaust Vent And Intake Air Pipe Installation 14 15 G Very Important Set up I...

Страница 4: ...rbon monoxide never operate this water heater unless it is properly vented and has an adequate air supply for proper operation Be sure to inspect the vent system for proper installation at initial sta...

Страница 5: ...ture and time with regard to scald injury and may be used as a guide in determining the safest water temper ature for your applications The temperature of the water in the heater can be regu lated by...

Страница 6: ...ning provided on the water heater at the time of installation No valve is to be placed between the relief valve and the water heater For circulating tank installation the separate storage tank s must...

Страница 7: ...ooster heaters are supplied with the Booster Installation kit In order to maintain proper temperature this kit must be correctly installed The Booster kit con tains the following list of parts 01 Nibc...

Страница 8: ...the vicinity of this or any other appliance Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighb...

Страница 9: ...tion failure This problem is especially noticeable in NEW LP installations and also in empty tank situations This can also occur when a utility company shuts off service to an area to provide maintena...

Страница 10: ...gas valve there is a 1 8 NPT plug This plug can be removed to attach a manometer You can attach a meter to the incoming gas drip leg by removing the cap and installing the meter The gas pressure must...

Страница 11: ...eater is approved for zero clearance to combustible construction b See illustration within this section of clearances for location of exit terminals of direct vent venting systems c This water heater...

Страница 12: ...ake air vent in a parking area where machinery may damage the pipe c When venting with a two pipe system maximum distance between intake air vent and exhaust vent is 6 feet 1 8 m Minimum distance betw...

Страница 13: ...ents Note There must be a minimum of 36 spacing between every 2 kit grouping Fig 3 1 Multiple Vents Fig 3 3 Multiple Stainless Steel Horizontal Vent Kit Installation Front View Location of exit termin...

Страница 14: ...LONGER VENT RUNS 1 The maximum combined equivalent length can be extended by increasing the diameter of both exhaust vent and intake air vent pipe equally However the transitions should begin a minim...

Страница 15: ...1 2m intervals to prevent sagging of the pipe where condensate may form 6 Do not use the water heater to support any piping 7 Ascreened straight coupling is provided with the water heater for use as a...

Страница 16: ...LP 301 L Rev 3 30 09 Note Spacing for multiple series of concentric vents should be the same as Multiple Vertical Vent in Fig 3 3 P 13 H CONCENTRIC VENT 16...

Страница 17: ...ization current read from Flame Rectification probe d8 0 Not used d9 1 Not used d10 Actual Status bus communication co connected nc not connected d11 32 Not used d12 Power On Hours Example Hours x 100...

Страница 18: ...ic maintenance under normal conditions However in unusually dirty or dusty conditions periodic vacuuming of the cover to maintain visibility of the display and indicators is recom mended E SHUTDOWN PR...

Страница 19: ...inside diameter plastic tubing It is very important that the condensate line is sloped away from and down to a suitable inside drain If the condensate outlet on the AdvantagePlus is lower than the dra...

Страница 20: ......

Страница 21: ...21 LP 301 D Rev 3 30 09...

Страница 22: ...United States RHEEM MANUFACTURING COMPANY 1241 Carwood Ct Montgomery AL 36117 In Canada Rheem Canada Ltd 125 Edgeware Road Unit 1 Bramptom ON L6Y 0P5 You may also obain technical assistance by callin...

Страница 23: ...RESTRICTION OR IN NEED OF REPAIR REPLACEMENT GAS SUPPLY PRESSURE DROPS BELOW 3 5 WC 0 87 kPa WHEN APPLIANCE FIRES ELECTRICAL APPLIANCE NOT GROUNDED ELECTRICAL POLARITY REVERSED FLAME WILL LIGHT BUT G...

Страница 24: ...er assistance F02 Interrupted or shorted upper temperature sensor Check the electrical connection to the appropriate temperature sensor if connection is okay replace bad sensor F03 Interrupted or shor...

Страница 25: ...ocked Vent Pressure Switch Open Until Corrected 1 Assure that the vent is not blocked 2 Check the blocked vent pressure switch operation by applying a jumper If the switch is not functioning properly...

Страница 26: ...26 N O T E S...

Страница 27: ...27 N O T E S...

Страница 28: ......

Отзывы: