Rheem 86H-25 Скачать руководство пользователя страница 4

 

 

Diagram 6. 

Electrical Connection o

f the Robertshaw “ST” 

Thermostat/Thermal Cut-out 

 

MAINTENANCE 

Rheem recommends annual inspections and if required 
servicing by a qualified person to ensure safety, peak 
performance, longevity and avoid potential loss of warranty of 
this appliance. 
 

ISOLATION OF THE WATER HEATER 

The water heater should be switched off for servicing or if it is 
not used for long periods of time (eg. vacation). 
Isolate the water heater according to following steps: 

 

Isolate/switch  off  the  electrical  power  supply  to  the 
appliance.

 

 

Close the cold water supply stopcock valve at the inlet of 
heater 

– refer Diagram 6.

 

 
 

TEMPERATURE AND PRESSURE RELIEF (TPR) VALVE 

 

It is recommended that routine preventative maintenance 
is  carried  out  at  least  once  every  6  months  to  remove 
lime  deposits  and  verify  that  the  valve  is  operating 
correctly and the discharge line is not blocked.  Failure of 
routine  inspection  may  result  in  the  water  heater 
exploding.   

 

Continuous leakage of water from the valve may indicate 
a problem with the water heater. 

 

To  manually  operate,  carefully  lift  and  release  the  lever 
handle  on  the  TPR  valve  to  ensure  the  valve  operates 
freely  and  allow  several  litres  of  water  to  flush  through 
the  discharge  line.    Ensure  the  discharge  water  is 
directed  to  the  floor  drain.    Avoid  any  contact  with  the 
discharge water to avoid scalding. 

 

If  there  is  no  water  flowing  out,  please  contact  a 
serviceman.

 

 

Damage  to  the  water  heater  due  to  blockage/restriction 
at  the  overflow  outlet  will  void  the 

manufacturer’s 

warranty.

 

 

DRAINING THE HEATER AND T&PR REPLACEMENT 
Warning!  Beware of high temperature water. 

 

First, disconnect all power to the water heater. 

 

Turn off the cold water supply to the heater. 

 

Release the pressure in the heater by carefully operating 
the TPR valve release lever/knob. 

 

Undo the cold water inlet union. Attach a hose to the 
heater side of the union. Drain the hose to waste. 

 

Operate the TPR valve release lever/knob allowing air 
into the heater and water to drain via the hose. 

 

Remove and replace the TPR valve 

– beware of hot 

water. 

 

To fill heater refer to instruction “Filling the Water Heater”

 

WARRANTY CONDITIONS 

RHEEM MANUFACTURING COMPANY (SINGAPORE) PTE LTD, representing Rheem Water Heating Appliances will guarantee the 
heater for a period of twelve months from the date of original installation and operation against defect through faulty materials and 
workmanship.   
RHEEM MANUFACTURING COMPANY (SINGAPORE) PTE LTD will warrant replacement of any part or parts which prove to have 
been defective and which have not been misused or carelessly handled.  Rheem reserve the right to decline responsibility where 
installation has been incorrectly carried out 

and not in accordance with the manufacturer’s instructions which accompany each 

appliance.  Where a failed component is replaced under warranty, the balance of the original heater warranty will remain effective.  The 
warranty only applies to the water heater and does not cover any plumbing connected to the heater, eg. pressure limiting valve, stop 
cock, non return valve, etc.  Dated proof of purchase is required prior to commencement of warranty work. 

 

COMMON FAULTS AND REMEDIES 

 

Fault 

Possible Causes 

Remedies 

No hot water flowing out 

1)  Cold water inlet supply to heater is closed. 
2)  Pipes are blocked 
3)  Water supply is cut off by Utility 

1)  Turn on the inlet tap 
2)  Dredge the pipe by plumbers 

Water temperature 

is not hot 

1)  Terminal block is damaged 
2)  Earth Leakage Circuit Breaker (ELCB) has operated. 
3)  Element has failed 
4)  ECO has activated (Hi Limit) 
5)  Set temperature is too low 
6)  Thermostat is damaged 
7)  Water Heater is working 

1)  Call electrician 
2)  Call electrician 
3)  Call electrician 
4)  Call electrician 
5)  Raise the set temperature 
6)  Call electrician 
7)  Please wait for a while 

Abnormal noise is 

coming from the water 

heater and pipelines 

1)  Heating up noise 
2)  Abnormal sound in pipeline when mains pressure is 

not stable 

3)  Scaling on heater element 
4)  Water Hammer 

1)  Normal 
2)  Normal. Close the cold water inlet tap for a while. 
3)  Contact a serviceman 
4)  Contact a serviceman 

TPR Temperature and 

Pressure Relief Valve is 

discharging water 

1)  Expansion of water during heating up 
2)  Valve is blocked by foreign materials 
3)  Excessive cold water pressure 

1)  Normal 
2)  Operate valve lever to remove dirt deposit 
3)  Reduce incoming water pressure 

 

Rheem Water Heating Appliances 

Rheem Manufacturing Company (Singapore) Pte Ltd 

VN 093 00 01 - 04

 