65
TABLE 13
802V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS
K
ey
F
AULT
CODES
FAUL
T
CODES
D
I
SPLAYED
TE
X
T
DESCR
I
PT
I
ON
FAULT
CODE
D
I
SPLAYED
AT
DUAL
SEVEN
-
SEGMENT
D
I
SPLAY
OF
CONTROL
NO
MODEL
DATA
DESCR
I
PT
I
ON:
Th
i
s
code
i
s
d
i
sp
l
ayed
anyt
i
me
there
i
s
no
mode
l
data
at
the
furnace
or
(for
commun
i
cat
i
ng
systems
on
l
y)
on
the
networ
k
(e
.
g
.
at
the
condenser
or
thermostat)
.
The
mode
l
data
i
s
e
l
ectron
i
ca
ll
y
stored
data
that
i
s
used
to
def
i
ne
(among
other
th
i
ngs)
b
l
ower
operat
i
on
.
W
i
thout
the
mode
l
data,
the
furnace
can
not
funct
i
on
.
Note
that
mode
l
data
may
be
ava
il
ab
l
e
even
i
f
there
i
s
no
card
attached
to
the
furnace
contro
l.
A
m
i
ss
i
ng
memory
card
w
ill
d
i
sp
l
ay
fau
l
t
code
"d4"
i
f
mode
l
data
i
s
ava
il
ab
l
e
on
the
networ
k.
SOLUT
I
ON
SOLUT
I
ON:
Rep
l
ace
the
m
i
ss
i
ng
memory
card
i
nto
the
connector
l
abe
l
ed
P6
on
the
furnace
contro
l
(
I.
F
.
C
.
)
. I
f
the
or
i
g
i
na
l
card
can
not
be
found,
a
rep
l
acement
card
can
be
ordered
from
ProStoc
k.
Be
sure
to
order
the
correct
memory
card
for
the
furnace
.
Note:
Furnace
power
must
be
cyc
l
ed
off
and
then
on
aga
i
n
after
rep
l
ac
i
ng
the
card
or
the
mode
l
data
w
ill
not
be
read
.
d
6
HORSEPOWER
CONFL
I
CT
ON
MEMORY
CARD
DESCR
I
PT
I
ON:
The
horsepower
reported
by
the
motor
does
not
match
the
horsepower
stored
i
n
memory
i
n
the
mode
l
data
of
the
memory
card
. H
owever,
the
mode
l
data
stored
on
the
m
i
croprocessor
of
the
furance
contro
l
does
match
the
attached
motor
.
CAUSE:
There
are
two
poss
i
b
l
e
causes
for
th
i
s
fau
l
t:
(1)
The
b
l
ower
motor
has
recent
l
y
been
rep
l
aced
and
the
wrong
horspower
motor
was
used
.
(2)
The
memory
card
or
furnace
contro
l
has
recent
l
y
been
rep
l
aced
and
the
wrong
card
or
rep
l
acement
contro
l
was
used
.
SOLUT
I
ON:
Determ
i
ne
the
correct
motor
and
/
or
mode
l
data
card
for
the
furnace
and
rep
l
ace
the
i
ncorrect
or
damaged
part
w
i
th
a
new,
correct
part
.
N
eve
r
r
epla
c
e t
h
e mem
or
y
c
a
rd
o
f a fu
r
na
c
e wit
h
a mem
or
y
c
a
rd
f
ro
m an
o
t
h
e
r
fu
r
na
c
e
or
co
mp
o
nent
(
e.g.
co
n
d
ense
r
or
ai
r
h
an
d
le
r)
.
Do
ing s
o
co
ul
d
r
esult in imp
ro
pe
r
o
pe
r
ati
o
n
o
f t
h
e bl
o
we
r
w
h
i
ch
may
c
ause
d
amage t
o
t
h
e
h
eat ex
ch
ange
r
. If t
h
e
or
iginal mem
or
y
c
a
rd
f
or
t
h
e fu
r
na
c
e
co
nt
ro
l is available an
d
w
or
king, it must be
use
d
.
A
correct
rep
l
acement
memory
card
can
be
ordered
from
ProStoc
k.
Be
sure
to
have
the
furnace
mode
l
and
ser
i
a
l
number
ava
il
ab
l
e
when
order
i
ng
.
STATUS:
Th
i
s
i
s
a
non
-
cr
i
t
i
ca
l
fau
l
t
.
The
furnace
shou
l
d
operate
i
n
any
mode
.
d
4
NO
VAL
I
D
MODEL
DATA
ON
MEMORY
CARD
DESCR
I
PT
I
ON:
The
memory
card
i
nserted
i
nto
the
s
l
ot
at
pos
i
t
i
on
P6
of
the
furnace
contro
l i
s
corrupt
and
can
not
be
used
OR
there
i
s
no
memory
card
i
nsta
ll
ed
at
a
ll. H
owever,
a
va
li
d
copy
of
mode
l
data
for
the
furnace
st
ill
res
i
des
i
n
the
furnace
m
i
croprocessor
.
CAUSE:
Th
i
s
fau
l
t
i
s
d
i
sp
l
ayed
when
there
i
s
no
i
nformat
i
on
on
the
memory
card
(b
l
an
k
),
the
card
i
s
not
present
or
the
memory
card
has
corrupted
and
can
not
be
proper
l
y
read
.
SOLUT
I
ON:
Remove
the
memory
card
and
rep
l
ace
w
i
th
the
original
memory
card
from
the
furnace
or
the
correct
rep
l
acement
memory
card
.
N
eve
r
r
epla
c
e t
h
e mem
or
y
c
a
rd
o
f a fu
r
na
c
e wit
h
a mem
or
y
c
a
rd
f
ro
m an
o
t
h
e
r
fu
r
na
c
e
or
co
mp
o
nent
(
e.g.
co
n
d
ense
r
or
ai
r
h
an
d
le
r)
.
Do
ing s
o
co
ul
d
r
esult in imp
ro
pe
r
o
pe
r
ati
o
n
o
f t
h
e bl
o
we
r
w
h
i
ch
may
c
ause
d
amage t
o
t
h
e
h
eat ex
ch
ange
r
. If t
h
e
or
iginal mem
or
y
c
a
rd
f
or
t
h
e fu
r
na
c
e
co
nt
ro
l is available an
d
w
or
king, it must be use
d
.
A
correct
rep
l
acement
memory
card
can
be
ordered
from
ProStoc
k.
Be
sure
to
have
the
furnace
mode
l
and
ser
i
a
l
number
ava
il
ab
l
e
when
order
i
ng
.
CAUSE:
Typ
i
ca
ll
y,
the
memory
card
w
ill
be
m
i
ss
i
ng
from
the
furnace
. I
n
most
cases,
the
cause
of
th
i
s
fau
l
t
w
ill
be
the
l
oss
or
d
i
sconnect
i
on
of
the
or
i
g
i
na
l
memory
card
from
the
furnace
contro
l
(or
I.
F
.
C
.
)
.
When
the
furnace
contro
l
(or
I.
F
.
C
.
)
i
s
rep
l
aced,
the
memory
card
must
be
saved
and
i
nsta
ll
ed
i
n
the
rep
l
acement
contro
l.
d
1
STATUS:
Th
i
s
i
s
a
non
-
cr
i
t
i
ca
l
fau
l
t
.
The
furnace
shou
l
d
operate
i
n
any
mode
.
CAUSE
STATUS
STATUS:
Th
i
s
i
s
a
cr
i
t
i
ca
l
fau
l
t
.
The
furnace
w
ill
not
operate
i
n
any
mode
.
E
X
PECTED
OPERAT
I
ON
E
X
PECTED
OPERAT
I
ON:
No
operat
i
on
(
i
nc
l
ud
i
ng
thermostat)
w
ill
be
perm
i
tted
w
i
thout
the
mode
l
data
.
The
mode
l
data
def
i
nes
the
I
BM
(
I
ndoor
B
l
ower
Motor)
speed
-
torque
curve
.
W
i
thout
th
i
s
i
nformat
i
on,
the
I
BM
can
not
operate
.
Refer
to
the
sect
i
on
of
th
i
s
manua
l
t
i
t
l
ed
"
I
NTEGRATED
FURNACE
CONTROL"
under
the
subsect
i
on
t
i
t
l
ed
"MEMORY
CARD"
for
deta
il
s
on
the
h
i
erarchy
of
use
of
mu
l
t
i
p
l
e
cop
i
es
of
mode
l
data
and
d
i
str
i
but
i
on
(among
other
deta
il
s)
of
mode
l
data
.
E
X
PECTED
OPERAT
I
ON:
mode
l
data
from
the
memory
card
can
not
be
used
because
i
t
i
s
i
nva
li
d
or
not
present
at
a
ll.
Operat
i
on
shou
l
d
proceed
as
norma
l
w
i
th
th
i
s
fau
l
t
(d4)
on
l
y
be
i
ng
d
i
sp
l
ayed
dur
i
ng
the
standby
mode
.
E
X
PECTED
OPERAT
I
ON:
mode
l
data
from
the
memory
card
can
not
be
used
because
i
t
i
s
i
nva
li
d
.
Operat
i
on
shou
l
d
proceed
as
norma
l
w
i
th
th
i
s
fau
l
t
(d6)
on
l
y
be
i
ng
d
i
sp
l
ayed
dur
i
ng
the
standby
mode
.
Diagnostics
Содержание 802V SERIES
Страница 68: ...68 Diagnostics TABLE 13 continued 802V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Страница 80: ...80 CM 0616...