Air
Electrical and Physical Data
14AJM Series
36
Model
Number
14AJM
ELECTRICAL
PHYSICAL
Phase
Frequency (Hz)
Voltage (Volts)
Compressor
Fan Motor
Full Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Fuse or HACR
Circuit Breaker
Outdoor Coil
Refrig.
Per
Circuit
Oz. [g]
Weight
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Minimum
Amperes
Maximum
Amperes
Face Area
Sq. Ft. [m
2
]
No.
Rows
CFM [L/s]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
Rev. 6/14/2012
18
1-60-208/230
9/9
48
0.8
12/12
15/15
20/20
16.39 [1.52]
1
2805[1324] 112 [3175] 154 [69.9] 171 [69.9]
24
1-60-208/230
13.5/13.5
58.3
0.8
18/18
25/25
30/30
16.39 [1.52]
1
2805[1324] 105.6 [2994] 154 [69.9] 171 [69.9]
30
1-60-208/230
12.8/12.8
64
1.4
18/18
25/25
30/30
16.39 [1.52]
1
2915[1376] 112 [3175] 157 [71.2] 175 [71.2]
36
1-60-208/230
16.7/16.7
79
1.9
23/23
30/30
35/35
21.85 [2.03]
1
3435[1621] 130.4 [3697] 181 [82.1] 201 [82.1]
42
1-60-208/230
17.9/17.9
112
2.8
26/26
30/30
40/40
21.85 [2.03]
1
3550[1675] 145.12 [4114] 205 [93] 225 [93]
48
1-60-208/230
21.8/21.8
117
2.8
31/31
40/40
50/50
21.85 [2.03]
2
4310[2034] 216 [6124] 249 [112.9] 269 [112.9]
49
1-60-208/230
19.9/19.9
109
1.9
27/27
35/35
45/45
21.85 [2.03]
2
3615[1706] 213 [6039] 249 [112.9] 269 [112.9]
56
1-60-208/230
21.4/21.4
135
1.9
29/29
35/35
50/50
21.85 [2.03]
2
3615[1706] 241 [6832] 254 [115.2] 274 [115.2]
60
1-60-208/230
26.4/26.4
134
2.8
36/36
45/45
60/60
21.85 [2.03]
2
4310[2034] 240 [6804] 254 [115.2] 274 [115.2]
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
[ ] Designates Metric Conversions