Safety Precautions

Do

turn off power to water heater if

it has been subjected to over heating,
fire, flood, physical damage.

Do Not

turn on water heater unless it

is filled with water.

Do Not

turn on water heater if cold

water supply shut-off valve 
is closed.

If there is any difficulty in
understanding or following the
Operating Instructions or the 
Care and Cleaning section, it is
recommended that a qualified person
or serviceman perform the work.

Operating the water heater.

CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a

long period of time (generally two weeks or more). HYDROGEN GAS IS EXTREMELY FLAMMABLE!! To dissipate such
gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink
before using any electrical appliance connected to the hot water system. If hydrogen is present, there will be an unusual sound
such as air escaping through the pipe as the water begins to flow. Do not smoke or use an open flame near the faucet at the
time it is open.

CAUTION: The cause 

of the high temperature
condition must be investigated
by qualified service technician
and corrective action must 
be taken before placing the
water heater in service again.

Safety Controls

The water heater is equipped with a
combination thermostat and temperature
limiting control (ECO) that is located
above the heating element in contact with
the tank surface. If for any reason the water
temperature becomes excessively high, the
temperature limiting control (ECO) breaks
the power circuit to the heating element.
Once the control opens, it must be reset
manually.

To reset the temperature limiting control:

Turn off the power to the water
heater.

Remove the jacket access panel(s)
and insulation. 

The thermostat protective cover
should not be removed. 

Press the red RESET button. 

Replace the insulation and jacket
access panel(s) before turning on the
power to the water heater.

Emergency Instructions

WARNING: If the water heater has been

subjected to flood, fire, or physical damage,
turn off power and water to the water
heater. 

Do not operate the water heater again until
it has been thoroughly checked by
qualified service personnel.

Содержание 120 Volt

Страница 1: ...cancer birth defects or other reproductive harm 2 through 30 Gallon Capacity 120 and 240 Volt Models LISTED 786H AP10227 10 11 03 Printed in USA Use Care Manual With Installation Instructions for the...

Страница 2: ...ou can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Your safety and the safety of...

Страница 3: ...uctions in how to adjust the thermostat s DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from s...

Страница 4: ...with generic earthquake bracing instructions can be obtained from Office of the State Architect 400 P Street Sacramento CA 95814 or you may call 916 324 5315 or ask a water heater dealer However appl...

Страница 5: ...such a manner that the thermostat and element access panels can be removed to permit inspection and servicing such as removal of elements or checking controls The water heater and water lines should...

Страница 6: ...he suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and the check valve The expansion tank is designed with an air cush...

Страница 7: ...s or persons and to eliminate potential water damage Piping used should be of a type approved for hot water distribution The discharge line must be no smaller than the outlet of the valve and must pit...

Страница 8: ...l for wiring connections The branch circuit wiring should include either Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for...

Страница 9: ...vices other than those authorized by the manufacturer into onto or in conjunction with the water heater The use of unauthorized energy saving devices may shorten the life of the water heater and may e...

Страница 10: ...ection arrangement Typical side connection arrangement Relief Valve Insulation Installation CAUTION Ensure the T P Valve opening is not obstructed by the insulation Heat Trap For increased energy effi...

Страница 11: ...nt room to service heater Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Temperature and Pressure Relief Valve properly ins...

Страница 12: ...Do not smoke or use an open flame near the faucet at the time it is open CAUTION The cause of the high temperature condition must be investigated by qualified service technician and corrective action...

Страница 13: ...ure Setting The temperature of the water in the water heater can be regulated by setting the temperature dial of the adjustable surface mounted thermostat s located behind the jacket access panel s Du...

Страница 14: ...nd or replacement as operation with the anode rod removed will shorten the life of the glass lined tank and will exclude warranty coverage Care and cleaning of the water heater Draining the Water Heat...

Страница 15: ...y may be off Make sure electric supply to water heater and disconnect switch if used are in the ON position The thermostat may See the Temperature regulation of the water heater be set set too low sec...

Страница 16: ...below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service person...

Страница 17: ...ed below and number of parts desired CAUTION For your safety DO NOT attempt repair of electrical wiring thermostat s heating elements or other operating controls Refer repairs to qualified service per...

Страница 18: ...ER BEFO RE SERV ICING R E SE T R E S E T 140 130 120 110 100 90 T H E R M O D I S C TURN OFF POW ER BEFO RE SERV ICING 140 130 120 110 100 90 T H E R M O D I S C R E SE T R E S E T 140 130 120 110 10...

Страница 19: ...he Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following informat...

Страница 20: ...T TO ELECTRICAL DISTRIBUTION PANEL JUNCTION BOX N 120 V Plug Connected Cord Set ONLY SINGLE ELEMENT FIG B BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL UPPER THERMOSTAT HIGH TEMP LIMIT ECO 2 UPPER H...

Отзывы: