1.  Before operation 
(1) Wear safety glasses or goggles 
(2) Do not connect the air supply 
(3) Inspect screw tightness 
(4) Check operation of the contact arm & trigger if moving smoothly 
(5) Connect the air supply 
(6) Check the air-leakage.(the tool must not have the air-leakage.) 
(7) Hold the tool with finger-off the trigger, then push the contact arm against the work-

pieces.(the tool must not operate.) 

(8) Hold the tool with contact arm free from work-piece and pull the trigger.(the tool must not 

operate.) 

 
2.  Operation 
Keep hands and body away from the discharge outlet when driving the fasteners because of 
dangerous of hitting the hands or body by mistake. 
 
Nail loading 
(1) Disconnect the air hose. 
(2)  Pull  the  NAIL  FEEDER  (324020)  down  to  MAGAZINE  (310830)  end,  fix  NAIL  FEEDER          
(324020) on STRAIGHT PIN (324040). 
(3) MAGAZINE COVER B (310840) is opened, feed a strip staples into MAGAZINE (310830), 
slide it towards to NOSE (211170), then feed the second strip, this magazine is capable for two 
strips staples. 
(4) Press STRAIGHT PIN (324040) down, the NAIL FEEDER (324020) is returned back to          
push stales into NOSE (211170). 
(5) Check the staples displayed in magazine compactly and smoothly.  
(6) Connect the air hose. 
 
Test operation 
(1) Adjust the air pressure at 70psi. (5 bar) and connect the air supply. 
(2) Without touching the trigger, depress the contact arm against the work-piece. Pull the 

trigger.(the  tool must fire the fastener.) 

(3) With the tool off the work-piece, pull the trigger. Then depress the contact arm against the 

work-piece.(the tool must fire the fastener.) 

(4) Adjust the air pressure as much as the lowest possible according to the diameters and 

length of fastener and the hardness of work-piece. 

 
 

Содержание N5021

Страница 1: ...nderstand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual b...

Страница 2: ...ailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing approp...

Страница 3: ...essional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevent...

Страница 4: ...vels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER...

Страница 5: ...henever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Страница 6: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Страница 7: ...ion mode Contact actuation Magazine capacity 150 staples Maximum allowable pressure 8 3 bar 120psi Recommended pressure range 5 bar to 7 bar 70psi to 100psi Fasteners Only the staple sizes shown in th...

Страница 8: ...ply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The fema...

Страница 9: ...wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air f...

Страница 10: ...wn to MAGAZINE 310830 end fix NAIL FEEDER 324020 on STRAIGHT PIN 324040 3 MAGAZINE COVER B 310840 is opened feed a strip staples into MAGAZINE 310830 slide it towards to NOSE 211170 then feed the seco...

Страница 11: ...the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In...

Страница 12: ...65 420160 PIN CAP B 21 323990 WASHER 66 324300 NUT 22 410910 BUMPER 67 310880 COVER A 23 110580 BODY 68 640460 ROLL PIN 2X40 24 410140 HANDLE GRIP 69 211180 NOSE COVER A 25 520370 END CAP SEAL 70 6100...

Страница 13: ...13 TOOL SCHEMATIC N5021...

Страница 14: ...14 IMPORTER NOBE ApS Bj dstrupvej 10 DK 8410 R nde Denmark Tel 45 8615 1913 E Mail info nobe dk www nobe dk www rgneurope com Wide Crown Stapler N5021 2016...

Отзывы: