background image

 

 

WARNING:  
 
The operating instructions shall draw attention to the following 

a) 

Only those fasteners listed in the operating instructions may be used in the fastener driving 

tools; 

NOTE:

 The fastener driving tool and the fasteners listed in the operating instructions must be 

seen as one unit system in terms of technical safety. 

b)

 Only the main energy and the lubricants listed in the operating instructions may be used; 

c)

 Fastener driving tools marked with an inverted equilateral triangle standing on one point 

may only be used with an effective safety yoke; 

d) 

Fastener driving tools equipped with contact actuation or continuous contact actuation, 

marked with the symbol “Do not use on scaffoldings, ladders”, shall not be used for specific 
application for example: 
when changing one driving location to another involves the use of scaffoldings, stairs, ladders, 
or ladder alike constructions, e.g. roof laths, closing boxes or crates, fitting transportation 
safety systems e.g. on vehicles and wagons; 

e)

 For the maintenance of fastener driving tools, only spare parts specified by the 

manufacturer or his authorized representative shall be used; 

f)

 Repairs shall be carried out only by agents authorized by the manufacturer or by other 

specialists, having due regard to the information given in the operating instructions; 

NOTE:

 Specialists are those who, as a result of professional training or experience, have 

sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant 
governmental industrial protection provisions, accident prevention regulations, directives and 
generally recognized technical regulations (e.g. CEN- and CENELEC-standards), to be able to 
assess the safe working condition of fastener driving tools. 

g)

 Stands for mounting the fastener driving tools to a support for example a work table, shall 

be designed and constructed by the stand manufacturer, in such a way that the fastener 
driving tool can be safely fixed for the intended use, thus for example avoiding damage, 
distortion or displacement. 

 

Additional instructions for fastener driving tools operated by compressed air 

a)

 Fastener driving tools operated by compressed air shall only be connected to compressed 

air lines where the maximum allowable pressure cannot be exceeded by a factor of more than 
10%, which can for example be achieved by a pressure reduction valve which includes a 
downstream safety valve; 

b)

 When using fastener driving tools operated by compressed air, particular attention must be 

paid to avoid exceeding the maximum allowable pressure; 

c) 

Fastener driving tools operated by compressed air should only be operated at the lowest 

pressure required for the work process at hand, in order to prevent unnecessarily high noise 
levels, increased wear and resulting failures; 

d)

 Hazards caused by fire and explosion when using oxygen or combustible gases for 

operating compressed air operated fastener driving tools. 

 
 
 

Содержание CN90

Страница 1: ...understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual...

Страница 2: ...ailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing approp...

Страница 3: ...essional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevent...

Страница 4: ...vels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER...

Страница 5: ...henever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and...

Страница 6: ...may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at...

Страница 7: ...ine capacity 225 275 nails Maximum allowable pressure 8 3 bar 120psi Recommended pressure range 5 bar to 7 bar 70psi to 100psi Fasteners Only the nail sizes shown in the table below can be driven with...

Страница 8: ...ply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The fema...

Страница 9: ...wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air f...

Страница 10: ...ng the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 200070 to open DOOR 210050 then open MAGAZINE COVER 420190 3 Adjust the height of NAIL SUPPORT 420210 according to...

Страница 11: ...the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In...

Страница 12: ...BUMPER A 78 640340 ROLL PIN 3X16 26 410120 BUMPER B 79 420110 FILTER 27 610330 NUT M6 Nylock 80 110030 END CAP 28 420180 GUARD COVER 81 510760 O RING 58X3 55 29 323290 SAFETY 82 630020 SNAP RING 52 30...

Страница 13: ...13 TOOL SCHEMATIC CN90...

Страница 14: ...14 IMPORTER NOBE ApS Bj dstrupvej 10 DK 8410 R nde Denmark Tel 45 8615 1913 E Mail info nobe dk www nobe dk www rgneurope com Industrial Coil Nailer CN90 2016...

Отзывы: