Chapter 3: Using Your Product
VENUS X1PRO-E
User Manual
35
Standard
>
Split
>>
->Preview
>>
Stand Alone Mode
>>
->Output Resolution
>>
Presentation Mode
>>
Switching Time
0.1s
Output Resolution
>>
->Presentation Mode
>>
Switching Time
0.1s
->Presentation Mode
Normal
Image 1 Source
DVI1
Width
1300
Height
1080
->H Pos
0
V Pos
0
EDID
>>
Reset Parameters
3.6 Preview Mode
Each of two output channels can have individually resolution, Output port DVI 1 & DVI 2 default
as PST output, DVI 3 & DVI 4 default to PGM output.
Scale the image, zoom the image and image quality setting.
1. Push the [MENU] button, turn the rotary knob, select <Preview>.Push the knob button, and
enter to preview mode, the mode including three functions: <Output Resolution>, <Presentation
Mode>, <Switching Time>. turn the rotary knob, select different function to set parameters.
Output Resolution setting same as standard mode.
2. Turn the rotary knob, select <Presentation Mode>.
3. There are four modes, <Normal>, <PIP>, <Split H>, <Split V>, select different mode, items
menus will show as follows:
Normal Modes