background image

© Xiamen RGBlink Science & Technology Co., Ltd.
Ph: +86 592 5771197

[email protected] | www.rgblink.com

40

Command

Function

Command packet

Note

One Push mode 8x 01 04 35 03 FF
5000k

8x 01 04 35 04 FF

Manual

8x 01 04 35 05 FF

6500k

8x 01 04 35 06 FF

CAM _RGain

Reset

8x 01 04 03 00 FF

Manual Control of R Gain

Up

8x 01 04 03 02 FF

Down

8x 01 04 03 03 FF

Direct

8x 01 04 43 00 00 0p 0q FF

pq: R Gain

CAM_ Bgain

Reset

8x 01 04 04 00 FF

Manual Control of B Gain

Up

8x 01 04 04 02 FF

Down

8x 01 04 04 03 FF

Direct

8x 01 04 44 00 00 0p 0q FF

pq: B Gain

CAM_AE

Full Auto

8x 01 04 39 00 FF

Automatic Exposure mode

Manual

8x 01 04 39 03 FF

Manual Control mode

Shutter priority

8x 01 04 39 0A FF

Shutter Priority Automatic Exposure

mode

Iris priority

8x 01 04 39 0B FF

Iris Priority Automatic Exposure

mode

Bright

8x 01 04 39 0D FF

Bright mode

CAM_Shutter

Reset

8x 01 04 0A 00 FF

Shutter Setting

Up

8x 01 04 0A 02 FF

Down

8x 01 04 0A 03 FF

Direct

8x 01 04 4A 00 00 0p 0q FF

pq: Shutter Position

CAM_Iris

Reset

8x 01 04 0B 00 FF

Iris Setting

Up

8x 01 04 0B 02 FF

Down

8x 01 04 0B 03 FF

Direct

8x 01 04 4B 00 00 0p 0q FF

pq: Iris Position

CAM_Gain Limit

Gain Limit

8x 01 04 2C 0p FF

p: Gain Positon

CAM_Bright

Reset

8x 01 04 0D 00 FF

Bright Setting

Up

8x 01 04 0D 02 FF

Down

8x 01 04 0D 03 FF

Direct

8x 01 04 4D 00 00 0p 0q FF

pq: Bright Positon

CAM_ExpComp

On

8x 01 04 3E 02 FF

Exposure Compensation ON/OFF

Off

8x 01 04 3E 03 FF

Reset

8x 01 04 0E 00 FF

Exposure Compensation Amount

Setting

Up

8x 01 04 0E 02 FF

Down

8x 01 04 0E 03 FF

Direct

8x 01 04 4E 00 00 0p 0q FF

pq: ExpComp Position

CAM_Back Light

On

8x 01 04 33 02 FF

Back Light

Compensation

Off

8x 01 04 33 03 FF

CAM_WDRStrength

Reset

8x 01 04 21 00 FF

WDR Level Setting

Up

8x 01 04 21 02 FF

Down

8x 01 04 21 03 FF

Direct

8x 01 04 51 00 00 00 0p FF

p: WDR Level Positon

CAM_NR

2D

8x 01 04 53 0p FF

P=0-7 0:OFF

CAM_NR

3D

8x 01 04 54 0p FF

P=0-8 0:OFF

CAM_Gamma

8x 01 04 5B 0p FF

p = 0 – 4

0

Default 1

0.45 2

Содержание RGB20X-POE-WH

Страница 1: ...PTZ Camera User Manual Article No RGB RD UM PTZ E001 Version V1 0 RGB20X 30X POE WH...

Страница 2: ...Dial Switch 10 2 1 3 RS 232 Interface 10 2 2 Bracket Mount 12 Chapter 3 Use Your Product 15 3 1 Video Output 15 3 1 1 Power on initial configuration 15 3 1 2 Video Output 15 3 2 Remote Controller 16 3...

Страница 3: ...ct 35 Chapter 5 Support 36 5 1 Contact us 36 5 2 Camera Maintenance and Troubleshooting 37 5 2 1 Camera Maintenance 37 5 2 2 Troubleshooting 37 Chapter 6 Appendix 39 6 1 VISCA Protocol List 39 6 1 1 C...

Страница 4: ...e case of special systems and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of compliant RGBlink can repair the fault or provide...

Страница 5: ...protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Use the Proper Power Cord Use only the power cord and connector specified for your prod...

Страница 6: ...space for all components Electric Safety Installation and operation must accord with electric safety standard Polarity of power supply The power supply of the product is 12V the max electrical current...

Страница 7: ...link com 6 Chapter 1 Your Product 1 1 In the Box Power Adapter 1 RS232 serial port line 1 Remote control 1 1 2 Product Overview 1 2 1 Product Model The User Manual is applicable to 20X PTZ Camera RGB2...

Страница 8: ...racy step driving motor mechanism it works extremely quiet and moves smoothly and very quickly to designated position 6 Multi Format Video Outputs support HDMI 3G SDI The 3G SDI is available for 100m...

Страница 9: ...Code Stream Double streams outputs simultaneously Video Compression forma H 265 H 264 Control Signal Interface RS 232 Ring through RS232 output RS 485 Control Protocol Protocol VISCA Pelco D Pelco P...

Страница 10: ...ontrol Interface input 11 HDMI Interface 2 Camera Base 7 RS232 Control Interface output 12 10 100M Network Interface 3 Remote Controller Receiver Light 8 RS485 Input left right 13 DC12V Input Power Su...

Страница 11: ...tom Dial Switch diagram two DIP switches are set to ON or OFF to select different modes of operation as shown in Table 2 1 Table 2 1 Dial Switch setting 2 1 3 RS 232 Interface 1 RS 232 interface Compu...

Страница 12: ...nal Ready 2 DSR Data Set Ready 3 TXD Transmit Data 4 GND System Ground 5 RXD Receive Data 6 GND System Ground 7 IR OUT IR Commander Signal IR 8 NC No Connection NO Port Definition 1 DCD Data Carrier D...

Страница 13: ...y Co Ltd Ph 86 592 5771197 support rgblink com www rgblink com 12 2 2 Bracket Mount Note Bracket can only be wall mounted or upside down mounted on template and concrete wall but can not be installed...

Страница 14: ...Xiamen RGBlink Science Technology Co Ltd Ph 86 592 5771197 support rgblink com www rgblink com 13 2 Upside down mount step...

Страница 15: ...Xiamen RGBlink Science Technology Co Ltd Ph 86 592 5771197 support rgblink com www rgblink com 14 Note The bracket mount is the optional accessory...

Страница 16: ...eo Output from LAN a Network Cable Connection Port refer to No 12 in Figure2 1 b Webpage Login Open your browser and enter 192 168 5 163 in the address bar factory default press Enter to enter into th...

Страница 17: ...Address Selection Select the camera address which wants to be controlled 3 Number Key Set or run 0 9 presets 4 Key Key combination use 5 Focus Control Key Auto Focus Enter into auto focus mode Manual...

Страница 18: ...nstruction press the key means a click rather than a long press and a special note will be given if a long press for more than one second is required 2 When a key combination is required do it in sequ...

Страница 19: ...the key is released 3 Zoom Control ZOOM IN press ZOOM key ZOOM OUT press ZOOM key Press and hold the key the camera will keep zooming in or zooming out and stops as soon as the key is released 4 Focus...

Страница 20: ...s not existed 3 Preset clearing to clear a preset position the user can press the CLEAR PRESET key first and then press the number key 0 9 to clear the relative preset Note press the key three times c...

Страница 21: ...n Home OK Press Home to confirm 3 3 2 System Setting Move the pointer to the Setup in the Main Menu click the HOME key and enter into the System Setting as shown below SETUP Protocol Auto Visca Addres...

Страница 22: ...d enter the EXPOSURE SET as follow EXPOSURE Mode Auto EV OFF BLC OFF Flicker 50Hz G Limit 3 DRC 2 Select Change Value Menu Back Mode Auto Manual Shutter priority Iris priority and Brightness priority...

Страница 23: ...COLOR in the Main Menu click the HOME and enter the COLOR SET as follow COLOR WB Mode Auto RG Tuning 0 BG Tuning 0 Saturation 100 Hue 7 AWB Sensitivity High Select Change Value Menu Back WB Mode Auto...

Страница 24: ...Off B W Mode color black white Gamma default 0 47 0 50 0 52 0 55 DZoom digital zoom options On Off DCI Dynamic Contrast Off 1 8 4 FOCUS Move the pointer to the FOCUS in the Menu click the HOME and ent...

Страница 25: ...Z in the Main Menu click the HOME and enter the P T Z as follow P T Z Speed by zoom ON Zoom speed 8 Image Freezing OFF Acc Curve Slow Select Change Value Menu Back Depth of Field Only effective for r...

Страница 26: ...mpatibility 2 Exit menu after modifying parameter to save it after powered off 3 3 6 Version Move the pointer to the VERSION in the Main Menu click the HOME and enter the VERSION as follow MCU Version...

Страница 27: ...camera and computer by network connecting cable Internet connection mode Connect the camera to Internet by Router or Switch and user can log in the device by browser Note Please do not put the power...

Страница 28: ...the camera Note The IP address to be added cannot be same with that of other computers or devices The existence of this IP address needs to be verified before adding 3 Click the Start and select Opera...

Страница 29: ...nd cancel no option for configuration Note Web access supported browsers IE 360 browser Google browser and other conventional browser 3 5 2 Preview After successful login into the management interface...

Страница 30: ...of the save then please reboot the camera to make new setting effect 3 6 2 Video Configuration 1 Video encoding Code stream Different video output mode setting use different streams Main stream secon...

Страница 31: ...ress comes up after setting Eg rtp 224 1 2 3 4000 udp 224 1 2 3 4000 4 Video Parameters A Focus Focus mode focus range focus sensitivity can be set Focus Mode set the focus mode the default auto manua...

Страница 32: ...nal E Noise Reduction 2D noise reduction 3D noise reduction and dynamic dead pixel correction available 2D Noise Reduction Set 2D noise reduction level default Auto 1 7 and Off optional 3D Noise Reduc...

Страница 33: ...address save changes and reboot the device to takes effect default 192 168 5 163 Note This IP address is the same with the one used to login Web page Subnet Mask Set the subnet mask default 255 255 2...

Страница 34: ...efault one day 2 10 days Optional NTP server address or domain name Set NTP server address or domain name default time nits gov Valid after setting NTP server synchronization NTP Server Port Sets the...

Страница 35: ...will fail Note After the version upgrade is complete you need to restore factory defaults a through web to restore the factory default configuration b through the recovery menu c remote control shortc...

Страница 36: ...Blink Science Technology Co Ltd Ph 86 592 5771197 support rgblink com www rgblink com 35 4 1 Product 981 0011 11 0 RGB20X POE WH 20X PTZ Camera support PoE 981 0011 15 0 RGB30X POE WH 30X PTZ Camera s...

Страница 37: ...Xiamen RGBlink Science Technology Co Ltd Ph 86 592 5771197 support rgblink com www rgblink com 36 Chapter 5 Support 5 1 Contact us...

Страница 38: ...a Remote control address is set to 1 if the machine is set back to the factory defaults remote control addresses need to be back to 1 too b Check whether the battery is installed on the remote control...

Страница 39: ...Xiamen RGBlink Science Technology Co Ltd Ph 86 592 5771197 support rgblink com www rgblink com 38...

Страница 40: ...l Command Command Function Command packet Note AddressSet Broadcast 88 30 0p FF p Address setting IF_Clear Broadcast 88 01 00 01 FF I F Clear CommandCancel 8x 21 FF CAM_Power On 8x 01 04 00 02 FF Powe...

Страница 41: ...Setting Up 8x 01 04 0A 02 FF Down 8x 01 04 0A 03 FF Direct 8x 01 04 4A 00 00 0p 0q FF pq Shutter Position CAM_Iris Reset 8x 01 04 0B 00 FF Iris Setting Up 8x 01 04 0B 02 FF Down 8x 01 04 0B 03 FF Dir...

Страница 42: ...0 6 120 7 130 8 140 9 150 10 160 11 160 12 180 13 190 14 200 CAM_IDWrite 8x 01 04 22 0p 0q 0r 0s FF pqrs Camera ID 0000 to FFFF SYS_Menu ON 8x 01 04 06 06 02 FF Turn on the menu screen OFF 8x 01 04 06...

Страница 43: ...0F 0F 0F 07 0F 0F 0F FF 6 1 3 Inquiry Command Command Function Command packet Note CAM_PowerInq 8x 09 04 00 FF y0 50 02 FF On y0 50 03 FF Off Standby CAM_ZoomPosInq 8x 09 04 47 FF y0 50 0p 0q 0r 0s F...

Страница 44: ...09 04 66 FF y0 50 02 FF On y0 50 03 FF Off CAM_ColorSaturationInq 8x 09 04 49 FF y0 50 00 00 00 0p FF p Color Gain setting 0h 60 to Eh 130 CAM_IDInq 8x 09 04 22 FF y0 50 0p FF p Gamma ID IR_ReceiveIn...

Страница 45: ...UM Upright 0xFF Address 0x00 0x0A Pan Speed Tilt Speed SUM DownLeft 0xFF Address 0x00 0x14 Pan Speed Tilt Speed SUM DownRight 0xFF Address 0x00 0x12 Pan Speed Tilt Speed SUM Zoom In 0xFF Address 0x00...

Страница 46: ...00 0x00 0xAF XOR Set Preset 0xA0 Address 0x00 0x03 0x00 Preset ID 0xAF XOR Clear Preset 0xA0 Address 0x00 0x05 0x00 Preset ID 0xAF XOR Call Preset 0xA0 Address 0x00 0x07 0x00 Preset ID 0xAF XOR Query...

Отзывы: