PTZ
User Manual
33
3.6.3 Network Configuration
1) Network port
Data port:
set the data port,the device will restart automatically after changed(default 3000,0-65535 optional).
Web Port:
Set Web port,the device will restart automatically after changed (default is 80,0-65535 is optional).
Onvif Port:
Set Onvif port,the device will restart automatically after changed(default 2000,0-65535 optional).
Soap Port:
Set Soap port (default 1936,0-65535 optional).
RTMP Port:
Set RTMP port (default 1935,0-65535 optional).
RTSP Port:
Set RTSP port,the device will restart automatically after changed (default 554,0-65535 optional).
Visca Port:
Set Visca port,the device will restart automatically after changed (default 3001,0-65535 optional).
Click on the "Save" button,it will be valid when display "Save successful".
RTMP access: RTMP: / / equipment IP address: 1935 / live/av0 (av0 main stream; av1 second stream)
RTMP Access : rtmp:// equipment IP address: 1935 / live/av0 (av0 main stream; av1 second stream)
2) Ethernet parameters
DHCP:
Enable or disable obtain IP automatically can be set. Save changes and reboot the device to takes effect
( Default:OFF)
IP Address:
Set the IP address,save changes and reboot the device to takes effect (default 192.168.5.163)
Note: This IP address is the same with the one used to login Web page.
Subnet Mask:
Set the subnet mask (default 255.255.255.0).
Default Gateway:
Set the default gateway (default 0.0.0.0).
Physical Address:
Set the physical address (the parameter is read-only but can not be modified).
Click on the "Save" button,it will be valid when display "Save successful". (Note: To prevent IP conflicts When
modify ).
3) DNS Parameters
Preferred DNS server:
set the preferred DNS server. (Default 0.0.0.0).
Alternate DNS server:
Alternate DNS server settings. (Default 0.0.0.0).
Click on the "Save" button,it will be valid when display "Save successful".
4) GB28181
Switch:
set whether open GB28181,can check
Time Synchronization:
whether synchronization time is set,you can check
Stream Type:
stream type setting (the default main stream,secondary stream optional)
Sign effective time (in seconds):
3600 Range 5-65535
Heartbeat time (seconds):
60 Range 1-65535
Register ID:
34020000001320000001
Register User name:
IPC
Register Password:
12345678
Equipment ownership:
Users can add their own
Administrative regions:
Users can add their own
Alarm Zone:
Users can add their own
Equipment installation address:
Users can add their own
Local SIP Port:
5060 Range 0-65535
GB28181 Server Address:
IP address of the computer
Server SIP Port:
5060 Range 0-65535
Server ID:
34020000002000000001
Click on the "Save" button,it will be valid when display "Save successful".
3.6.4 System Configuration
Содержание RGB12X-PTZ-WH
Страница 1: ...PTZ Camera User Manual Article No RGB RD UM PTZ E001 Version V1 0...
Страница 14: ...PTZ User Manual 14 2 Upside down mount step...
Страница 15: ...PTZ User Manual 15 Note The bracket mount is the optional accessory...
Страница 37: ...PTZ User Manual 37 Chapter 5 Support 5 1 Contact us...
Страница 39: ...PTZ User Manual 39...