RGBlink MSP 214 Скачать руководство пользователя страница 2

MSP 214 DVI to Fiber
Function Block Diagram

 

Operating Principle

MSP 214 DVI to Fiber transmitter is connected to 
computer, media player or HD camera, etc. User can 
connect the DVI interface on MSP 214 DVI to Fiber 
panel to PC with DVI cable, then connect the 
computer or media player, and MSP 214 DVI to 
Fiber transmitter to power supply. After the 
connection, the EQ Blance function starts 
automatically on MSP 214 DVI to Fiber transmitter. 
In order to avoid the damage of device, please use the 
standard power adapter. Fiber interface is used to 
connect to MSP 214 Fiber to DVI receiver.

Operation Manual

Function Block Diagram

Operating Principle

MSP 214 Fiber to DVI

MSP 214 Fiber to DVI receiver is connected to 

television (monitor) or LED screen which has DVI 

interface. Connect the fiber interface to the other fiber 

interface on MSP 214 DVI to Fiber transmitter with 

fiber cable, and then connect the DVI interface on 

MSP 214 Fiber to DVI panel to display device. After 

the connection, the EQ Blance starts automatically on 

the MSP 214 Fiber to DVI receiver. In order to avoid 

damaging the device, please use the standard power 

adapter.

Address: S601-607, S504 Weiye Building Torch Hi-Tech Industrial Development Zone, Xiamen, Fujian 

Province, P.R.C

Tel: 00865925771197                 Fax:00865925771202
Email: [email protected]   

  http://www.rgblink.com

MSP 214 Quick Start

Rev 1.3

Page 2 of 2

Common Questions and Solution

 Signal indicator light is off or blinks

 1. Check whether connect the DVI signal;
 2. Check whether the input signal, input wire and
 output wire are normal, the interfaces are in good
 connection;
 3. If above without problem, then the signal
 indicator is damaged.

Note: The indicator beside fiber interface is off 
when the device is in normal operation. It will light 
or blink if the fiber cable is in poor connection.

12V power interface poor contact

1. Check whether the power interface is in good 
    connection, if the interface is not tighten, screw
    it again.
2. Check whether any problem with adapter head, 
    replace it if there is any problem.
3. Check the power connector is loose, if so, please 
    send to professional personnel for repair.

Power indicator light is off or blinks

1. Check whether plug in the power cord, and has
    power supply;
2. Check whether the power cable is connected, and
    in good connection;
3. If above without problem, then the power
    indicator is damaged.