background image

 

DTR_319-01-01-001_EN_b

 

8.

 

Additional options 

8.1

 

Operator panel 

The operator panel is a separately offered accessory (additional option) which, among others, can work with the 
device.  On the panel, there are two monostable buttons that allow you to change the information displayed by 
the signalling device. An example of the panel is shown in Fig. 9

4

 

 

 

Fig. 10 

 

9.

 

Disposal and recycling 

9.1

 

Packaging material recycling 

The  packaging  elements  must  be  segregated  and,  then,  recycled  in  accordance  with  the  local  executive 
regulations on waste disposal. 

9.2

 

Device disposal 

 
The device must not be disposed of as urban waste! 

In accordance with the directive 2002/96/EC (WEEE), if the repair of the device is not economically justified, the 
user must take the damaged or destroyed equipment to a special waste disposal centre. 

 

 

10.

 

Most common installation errors 

1

 

Invalid configuration uploaded to the light signalling device.  

2

 

Drilling additional mounting holes. 

3

 

Installation not in accordance with the manual, that is wires facing up. 

                                                           

4

 Explanatory figure, the supplied panel may differ from the presented one 

Содержание 319-01-01

Страница 1: ...OPERATION AND MAINTENANCE MANUAL TL 70 2 Product code 319 01 01 Explanatory figure ...

Страница 2: ...1 1 Embedded user menu DEF microbutton 5 4 3 1 2 Interface transmission and communication speed parameters 6 5 Controller 6 5 1 Controller connectors 6 5 2 List of the LED module conectors 7 5 3 List of the signalling device connectors 7 5 3 1 RS 232 connector 8 5 3 2 RS 485 RS 422 connector 8 5 3 3 0 20mA digital current loop 8 5 3 4 Operator panel dry contact 8 6 Automatic brightness control of ...

Страница 3: ...ot bump during transportation Due to protective packaging the device should be stored in the temperature 25 C 60 C 13 F 140 F at the humidity below 99 RH 3 Device construction TL 70 2 is cased in a powder coated steel housing The properly installed device meets the IP65 tightness requirements 3 1 TL 70 2 construction The figure shows the TL 70 2 light signalling device2 det A roof det B controller...

Страница 4: ...tallation of the device ensures its proper operation and the maintenance of the device parameters like among others the housing tightness rating satisfying the required IP code NOTICE Before any installation or maintenance operations refer to the manual supplied by the manufacturer Improper connection to the mains power supply incautious device installation or improper use may cause the property d...

Страница 5: ...otocol with a control module such as a weighing terminal an operator panel 2 Determining the response to the events reported by the control module 4 3 1 Defining communication protocols 4 3 1 1 Embedded user menu DEF microbutton The user menu embedded in the device allows you to select a communication protocol display the information about the software version display the set protocol reset to the...

Страница 6: ...the default light signalling device protocol In addition in the devices with the Ethernet interface you can restore the default network layer settings IP address 192 168 0 11 network mask 255 255 255 0 and the communication port for the control module To restore the default settings you should during the normal operation of the device press the microbutton and hold it down until the inscription R ...

Страница 7: ...ctors Table 2 contains the description of the connectors in the light signalling device The connectors are accessible after the disassembly of the back cover and the LED module mounted on this cover det A device front det B controller det C back cover det D LED module Fig 9 NOTICE The housing should be disassembled with the disconnected power supply ...

Страница 8: ...he RS 485 or RS 422 connector Fig 7 using the control module 5 3 3 0 20mA digital current loop For the communication purposes the user connects with the controller via the digital current loop connector Fig 7 using the control module 5 3 4 Operator panel dry contact For the control purposes the user manipulates the operator panel or relay contacts 6 Automatic brightness control of the light signal...

Страница 9: ...gregated and then recycled in accordance with the local executive regulations on waste disposal 9 2 Device disposal The device must not be disposed of as urban waste In accordance with the directive 2002 96 EC WEEE if the repair of the device is not economically justified the user must take the damaged or destroyed equipment to a special waste disposal centre 10 Most common installation errors 1 I...

Отзывы: