![RFS OR2-SBLP2-21F Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/rfs/or2-sblp2-21f/or2-sblp2-21f_technical-handbook_1450465016.webp)
Radio Frequency Systems
16
6.3 Downlink Input/ Output Power Display
Input Power Range
Scale
Output Power Range
Scale
-85dBm
0 Segment
~-10dBm
0 Segment
-84 ~ -76dBm
1 Segment
-9 ~-4dBm
1 Segment
-75 ~ -67dBm
2 Segment
-3 ~ +2dBm
2 Segment
-66 ~ -58dBm
3 Segment
+3 ~ +8dBm
3 Segment
-57 ~ -33dBm
4 Segment
+9dBm~
4 Segment
[Table - 11] LCD DownLink Power Scale Display
6.4 Control
No.
Tact S/W#1
Tact S/W#2
Function
1
Release
(No Condition)
Push
(More than 3 Sec)
Top and Bottom Reversal
2
Push
(More than 3 Sec)
Push
(More than 3 Sec)
1. Enter FA Setup Mode(FA Flick)
2. Exit FA Setup Mode
3
Push
(Tick)
Release
(No Condition)
Move to Right FA (in FA Setup Mode)
4
Release
(No Condition)
Push
(Tick)
Move to Left FA (in FA Setup Mode)
5
Push
(More than 2 Sec)
Release
(No Condition)
Set/Clear Correspond to FA
6
Release
(No Condition)
Push
(More than 2 Sec)
Set/Clear Correspond to FA
[Table - 12] Tact Switch