Figure 7.0.4
Note that all DN-2400E/EP wireless bridges ordered as single units outside of the Starter Kit are shipped
configured as Remote units.
One DN-2400E/EP in each network must be configured as a Base. All traffic to and from other bridges in
the DN-2400E/EP network will flow through the base. Figure 7.0.4 shows a DN-2400E/EP being reconfig-
ured from a Remote to a Base.
A change to the Device Mode parameter and/or the RF Data Rate parameter will not take effect until the
Apply Changes Button is clicked and the DC power to the DN-2400E/EP is cycled off and back on. All
other parameter changes become effective when the Apply Changes button is clicked. Clicking the Re-
fresh button updates any changes in Current Settings or on the configuration tabs.
As discussed in Section 5, the default Transceiver Setup values allow a remote to immediately join to a
nearby unencrypted base. TX Power should be set to 10 dBm in Europe or 18 dBm in North America for
most installations. The 0 dBm default value is suitable for pretesting a DN-2400E/EP network on a table-
top before installation.