1.  Warranty Information 

 

 

Warranty Statement 

 

The RFL3200 UK-10 Unmanaged Ethernet Switch comes with a three-year warranty from the date of shipment and is 
warranted against defects in material and workmanship for three years. During the warranty period RFL will repair or, at its 
option, replace components that prove to be defective at no cost to the customer, except the shipping cost of the failed 
assembly. All equipment returned to RFL Electronics Inc. must have an RMA (Return Material Authorization) number, 
obtained by calling the RFL Customer Service Department at 973.334.3100 or e-mail 

[email protected]

   

defective part should be returned to the factory, shipping charges prepaid, for repair or replacement FOB Boonton, N.J.  
RFL warrants product repair from three-years from the date of repair or the balance of the original factory warranty, 
whichever is longer. 
 
This warranty does not apply if the equipment has been damaged by accident, neglect, misuse, or causes other than 
performed or authorized by RFL Electronics Inc. 
 
This warranty specifically excludes damage incurred in shipment to or from RFL. In the event an item is received in 
damaged condition, the carrier should be notified immediately. All claims for such damage should be filed with the carrier. 

 

NOTE

 

If you do not intend to use the product immediately, it is recommended that it be opened immediately after receiving and 
inspected for proper operation and signs of impact damage. 

 

 
This warranty is in lieu of all other warranties, whether expressed, implied or statutory, including but not limited to implied 
warranties of merchantability and fitness for a particular purpose. In no event shall RFL be liable, whether in contract, in 
tort, or on any other basis, for any damages sustained by the customer or any other person arising from or related to loss of 
use, failure or interruption in the operation of any products, or delay in maintenance or for incidental, consequential, 
indirect or special damages or liabilities, or for loss of business or other financial loss arising out of or in connection with 
the sale, lease, maintenance, use, performance, failure or interruption of the products. 

 

 

FCC Statement 

 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense. 

 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation.  
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  
 

 

Reorient or relocate the receiving antenna.  

 

Increase the separation between the equipment and receiver.  

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  

 

Consult the dealer or an experienced radio/TV technician for help. 

RFL3200 UK-10 User Guide

 

 

RFL Electronics Inc. 

October 6, 2010 

                         2 

973.334.3100 

Содержание RFL3200 UK-10

Страница 1: ...ng Information 15 Important The RFL 3200 UK 10 Unmanaged Ethernet Switch contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with this product please contact RFL using the contact information below for assistance RFL Electronics Inc 353 Powerville Road Boonton TWP NJ 07005 9151 USA Phone 973 334 3100 F...

Страница 2: ...oducts or delay in maintenance or for incidental consequential indirect or special damages or liabilities or for loss of business or other financial loss arising out of or in connection with the sale lease maintenance use performance failure or interruption of the products FCC Statement NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to...

Страница 3: ...0 carries a 3 year warranty Rear Compression Block for Power and Ground Connections Four RJ 45 Electric Connectors are always installed here Four pairs of Fiber connectors or four RJ 45 Electrical connectors can be installed here GigE high speed connections for either two RJ 45 electric connectors or two SFP cages for fiber heads LED Indicators for Ethernet ports Green Power ON Light The RFL3200 U...

Страница 4: ...the equipment properly and safely Throughout this User Guide warnings appear before procedures that are potentially dangerous and cautions appear before procedures that may result in equipment damage if not performed properly The instructions contained in these warnings and cautions must be followed exactly Warning Follow all of your company s policies and procedures regarding the installation of ...

Страница 5: ... and 1040 11 IEC 60825 1 2007 Laser light can potentially cause serious eye damage The lasers used in the RFL 3200 UK 10 produce light that is invisible to the naked eye It should be assumed that the laser is active at all times and it is imperative that the technician never look into the end of the fiber or the aperture with the naked eye or with optical instruments CAUTION Any installation using...

Страница 6: ...om the items listed Other mounting options may be available contact RFL at sales rflelect com Application Description Standard 19 Rack Mounting Mounting Brackets 2 and 4 screws for mounting the brackets to the RFL3200 UK 10 DIN Rail Mounting Adapter Kit installed under the unit Wall Mounting Mounting Brackets 2 and 4 screws for mounting the brackets to the RFL3200 UK 10 Ordering information can be...

Страница 7: ...liability and performance Units installed in enclosed cabinets should be well ventilated When operating at temperatures above 55 C 131 F a full 1U of chassis space must be left open above the installed RFL3200 UK 10 DIN Rail Installation When installation in a metric DIN type rack or cabinet is required RFL provides an adapter that is conveniently mounted under the unit as shown below Carefully in...

Страница 8: ...rely mount the RFL3200 UK 10 to the wall Mount the unit in the required location allowing enough space for convection cooling Un mounted Unit When installed in a lab or workplace setting ensure that there is an unobstructed view of the front of the unit for observation of the LED indicators Keep an open area around the unit so that cooling by convection can occur while the RFL3200 UK 10 is in oper...

Страница 9: ...ssion block that indicates which power supply was installed in the unit before leaving the factory Before proceeding with the power and ground wire installation check the power supply label to ensure that the unit will operate at the input voltage available WARNING The RFL3200 UK 10 must be properly grounded as described on the following page before attempting to connect input power Improper groun...

Страница 10: ...anently wired installation in restricted access locations only The RFL3200UK 10 contains fuses on both supply poles that are intended for replacement by qualified personnel only The following fuses are recommended 19 32V 115V 5x20 mm 2 amp 38 150V 250V 5x20 mm 1 amp 200 300V 250V 5x20 mm 0 25 amp 5 Strip back and connect the positive and negative leads from the station battery to the positive and ...

Страница 11: ...ance 3dB margin 100 Base FX 2 1310 nm Multimode ST 33 9 to 31dBm 22 5 to 14dBm Average into 50µm fiber 19 to 14dBm Average into 62 5µm fiber 14dB1 2 km 1 2 mi WAN Ports 9 10 SFP Base Units if installed available options SFP 100 Base FX B 104358 1 1310 nm Multimode LC 30dBm max 15 7dBm typical 14dB 2 km 1 2 mi SFP 100 Base LX C 104358 2 1310 nm Singlemode LC 31dBm max 15 to 8dBm 20dB 10 km 6 2 mi S...

Страница 12: ...ough 8 GigE ports 9 and 10 have integral LED indicators In the example shown ports 5 through 8 have fiber heads installed These ports can be ordered from the factory as RJ 45 Electrical Connectors LAN Ports 1 8 LED Indicators LED indicators 1 through 8 have two functions and will show the following a The state of the Ethernet connection and b The connection speed LED Condition Status LED ON Port i...

Страница 13: ...shown below Right green LED indicator Left green LED indicator LED indicators 9 and 10 have two functions and will show the following Left LED Right LED Status Off Off There is no link on the port Green Off 1000 Mb s link Blinking green Off 1000 Mb s data transfer Off Green 100 Mb s link Off Blinking green 100 Mb s data transfer Green Green 10 Mb s link Blinking green Blinking green 10 Mb s data t...

Страница 14: ...pter J IEC 60825 1 2007 Ethernet Port Specifications 802 3i 10 Base T 802 3u 100 Base TX 100 Base FX 802 3x Duplex and Flow Control 802 3AB 1000 Base T Power Supply Specifications Supply Voltage 19 32 Vdc 38 150 Vdc 96 132 Vac 50 or 60 Hz 200 300 Vdc 200 275 Vac 50 or 60 Hz Maximum Input Power 15 W Continuous Operating Temperature 30º C 22º F to 75º C 167º F Convection cooling only Operating Humid...

Страница 15: ...ectronics Inc On line Customer Resource Center has been created to provide customers with real time information necessary to keep RFL equipment operating optimally The Resource Center contains Application Notes Service Notices Product Bulletins Software Downloads Software Upgrades Technical Product Manuals and Sales Brochures in a convenient and easy to use location on our web site The Resource Ce...

Страница 16: ... may be reproduced or transmitted in any form or by any means electronic mechanical photocopy recording or otherwise or stored in any retrieval system of any nature unless written permission is given by RFL Electronics Inc This publication has been compiled and checked for accuracy The information in this publication does not constitute a warranty of performance RFL Electronics Inc reserves the ri...