9.  V.24 Data Ports (Channels B & C) 

 
Ports B and C are DCE ports on DB9 female connectors for asynchronous data: 
 

Channels B & C Ports Pin-out  – D9F on chassis (DCE) 

Circuit Pin 

Direction 

TxD Transmit 

Data 

Input 

RxD Receive 

Data 

Output 

RTS 

Request to Send 

Input 

CTS 

Clear to Send 

Output 

DCD 

Data Carrier Detect 

Output 

DTR 

Data Terminal Ready 

Input 

DSR 

Data Set Ready 

Output 

RI Ring 

Indicator 

Output 

SG Signal 

Ground 

 

Screen / Drain must be connected to the connector Shell 

 
 
RI is permanently OFF. 
DSR is ON when aggregate framing is synchronised. 
DTR is ignored. 
RTS turns on remote DCD and local CTS after a delay. 
 
 
Transceivers are specified to ± 15kV IEC1000-4-2 air discharge ESD protection and 
port connections are additionally protected by Tranzorb type arrays. 
 
 
DIP switches provide configure options for each port, see section 10. 
 
 

V.24 Port Sharing 

 
There are two methods by which multiple V.24 ports can be assigned to an 
aggregate channel: 
 

Channels (ports) B and C within an SMX3/21 unit are assignable to 
Aggregate Channels 2 and / or 3. 

 

Where two SMX3s are co-located and interconnected via the concatenation 
ports, it is possible for each of Channels B & C to be selected to communicate 
over either via X.21 aggregate channel or the concatenation port in which 
cases the channel terminates within the SMX3/21, via both ports, for daisy-
chain applications via a co-located SMX3/21. 

 

Where multiple V.24 ports are assigned to a channel (on one or multiple 
SMX3/21 units), data from the channel is presented at RxD of all ports other 
than the source of the data, and data to the channel is an ‘or’ function of TxD 
of those ports where RTS is asserted ON.  It is important therefore that 
equipment connected in this way, such as a SCADA system, has the self-
discipline for only one to be transmitting at any time. 

 

Содержание 21 Sub-MUX

Страница 1: ...s plc U U Ut t ti i il l li i it t ty y y N N Ne e et t tw w wo o or r rk k k S S Sp p pe e ec c ci i ia a al l li i is s st t ts s s SMX3 21 Sub MUX X 21 V 24 Dual Protocol sub rate multiplexer User...

Страница 2: ...rt 8 8 X 21 Data Port Channel A 10 9 V 24 Data Ports Channels B C 11 10 DIP Switches 13 11 LEDs 18 12 Power Input 19 13 Alarms 19 14 Example Configurations 20 15 Blank Setting Table 22 Issue Comments...

Страница 3: ...with reversible mounting brackets permitting either the connectors or the LEDs to face the front of the rack SMX3 21 aggregates one X 21 data channel Channel A and two V 24 data channels Channel B Ch...

Страница 4: ...Channel B is re transmitted onto a second point to point link at the aggregate level via the Concatenation Port For this to operate all links must be synchronised to the network master timing signal I...

Страница 5: ...ame regardless of aggregate speed Data Channel Aggregate Speed 64kbit s 128kbit s 192kbit s 256kbit s Channel A X 21 Bandwidth kbit s 64 64 or 128 Sample Rate 16k 32k 48k 64k Baud Rate range Async Mod...

Страница 6: ...arrays This port carries an aggregate of three bi directional data channels one X 21 channel and two V 24 channels Standard X 21 Port Pin out when in DTE configuration D15M on chassis Circuit Pin A P...

Страница 7: ...erived from within the unit in this case the Clock Source must be configured to Master In both cases the timing signal is output on pins 6 and 13 Optional X 21 Port Pin out when in DCE configuration D...

Страница 8: ...ection and port connections are additionally protected by Tranzorb type arrays Aggregate Concatenation Aggregate Concatenation is the interconnection at aggregate level of two co located SMX3 21 units...

Страница 9: ...on to a co located SMX3 21 requires a five twisted pair cross over cable with overall shield eg RS 111 8988 Maximum recommended length 10m check Utility standards Aggregate Concatenation Cable D15M D1...

Страница 10: ...Transceivers are specified to 15kV IEC1000 4 2 air discharge ESD protection and port connections are additionally protected by Tranzorb type arrays Data received at the Channel A port is always termin...

Страница 11: ...switches provide configure options for each port see section 10 V 24 Port Sharing There are two methods by which multiple V 24 ports can be assigned to an aggregate channel Channels ports B and C wit...

Страница 12: ...sm DTR is ignored and can be left unconnected the sub multiplexer assumes a continuous ON state DSR is ON when the Aggregate is working an in synchronism RI is unconnected or permanently OFF When RTS...

Страница 13: ...hes DIP Switch Locations Dip Switch functions SW1 SW2 SW3 SW4 SW5 SW6 Channel A X 21 Data configuration Channel B V 24 Data configuration Channel C V 24 Data configuration Not used Aggregate Concatena...

Страница 14: ...to Off When set to On data transmitted into of the MUX TxD is looped back to its RxD output Channel A requires the clock to be present as this is a DCE port the clock is sourced from the MUX provided...

Страница 15: ...lso be used for applications where asynchronous character formats are not specifically supported The baud rate settings are ignored See section 5 Async 8 bit is selected for 7 data bits plus 1 parity...

Страница 16: ...here network timing is unavailable The timing signal X is output on pins 6 and 13 Sa and Sb Timing must be selected Enabled as Concat ie DTE Timing X This is the normal setting for the Concatenation P...

Страница 17: ...the concatenation port from the co located unit When used in conjunction with the modes Enabled as DCE or Enabled as DTE Signal Timing X the timing signal received from the concatenation port will be...

Страница 18: ...able Note For units connected in a concatenated network data on aggregate channels 2 and 3 is broadcast to all configured V 24 ports regardless of whether there is equipment connected to those ports I...

Страница 19: ...ther Main Earth 13 Alarms Two alarm relays are incorporated energised when healthy Each relay provides a single changeover contact presented on a plug in terminal strip see equipment layout For a cont...

Страница 20: ...ck signal is provided by the X 21 links V 24 channels configured in Transparent mode DIP Switch Settings for both units 8 7 6 5 4 3 2 1 SW1 0 0 0 0 0 0 0 1 SW2 0 0 0 0 0 1 0 0 SW3 0 0 0 0 0 1 0 1 SW4...

Страница 21: ...igured in Transparent mode DIP Switch Settings for A1 C1 8 7 6 5 4 3 2 1 SW1 0 0 0 0 0 0 0 1 SW2 0 0 0 0 0 1 0 0 SW3 0 0 0 0 0 1 0 1 SW4 Not used SW5 0 0 0 0 0 0 0 1 SW6 0 1 0 0 0 0 0 0 DIP Switch Set...

Страница 22: ...able Location Reference DIP Switch Settings 8 7 6 5 4 3 2 1 SW1 SW2 SW3 SW4 SW5 SW6 2009 RFL Communications plc Connect 17 Avon Way Langley park CHIPPENHAM Wilts SN15 1GG www rflcomms co uk Installati...

Отзывы: