background image

 

     RX0696-3008-31 

    

EXPANSION SHELF 

 

 

 

INTRODUCTION 

 

The RFI Receiver Multicoupler Expansion Shelf is a wideband low loss 8 way splitter 
with high isolation between outputs and is available as an optional accessory for the 
range  of  RFI  Receiver  Multicouplers  to  expand  system  channel  capacity.  The 
Expansion Shelf is designed for broadband operation and is suitable for use with any 
model in the RFI Receiver Multicoupler range. 

INSTALLATION 

Mounting 

The Expansion Shelf is to be mounted indoors only. It is designed to fit in a 1U rack 
space and should be mounted clear of any equipment that generates excess heat. 

 

Earthing 

Connect an earthing strap from the chassis to an appropriate earth point to protect 
the Expansion Shelf from being exposed to high transient voltages. 

RF Input 

The  specified  maximum  signal  level  into  this  input  should  be  observed  to  avoid 
damaging the input circuitry. 

RF Outputs 1 to 8 

Eight  equal  level  N  connector  RF  outputs  are  available.  Best  performance  will  be 
achieved if 50 ohm terminations are fitted to any unused RF outputs however, as the 
outputs are well isolated from each other, the performance degradation is minimal if 
the unused RF outputs are left unterminated. 

Cabling 

Please  ensure  that  all cables to  the  Expansion  Shelf  are  properly  grounded to  avoid 
lightning  transients  travelling  to  the  unit.  If  the  Expansion  Shelf  is  located  some 
distance from the Receiver Multicoupler longer cables will be required. Only use high 
quality, well screened coaxial cables between units. 

Connection to the Receiver Multicoupler 

Connect  the  supplied  N  male  to  N  male  cable  from  the  Receiver  Multicoupler 
Expansion Port or RF Output (as determined by configuration) to the RF Input on the 
Expansion Shelf. 

Specifications - 

Typical at 25

 

Frequency range   

 

 

60- 960 MHz 

Insertion Loss: RF outputs 1-8   

10.5 ± 0.5 dB 

Insertion Loss variation with temp. 

±0.2 dB 

Impedance   

 

 

 

50 ohm 

Input return loss 

 

 

 

>14 dB 

Output return loss   

 

 

>14 dB 

Isolation between outputs 

 

>20 dB 

Maximum Input Level 

 

 

24 dBm 

RF Connectors  

 

 

 

N female 

Operating temperature range 

 

-30 to +60 

Earthing 

 

 

 

 

M6 earthing stud 

Mechanical Dimensions   

 

To fit a 1U high rack space 

 

 

 

 

 

 

44x482x120mm, including  

 

 

 

 

 

 

connectors 

Weight   

 

 

 

 

1.2 kg 

 