PROBLEM: Power ON/OFF switch does not illuminate when turned on.

PROBABLE CAUSE 

SUGGESTED REMEDY

No power in the AC outlet.

Check there is power in the outlet.

Internal Fuse Blown

Return the unit for Service

PROBLEM: AC side fuse blows as soon as power is turned on.

PROBABLE CAUSE 

SUGGESTED REMEDY

Unit is defective.

Return the unit for Service

PROBLEM: The output voltage is 0 V or very low.

PROBABLE CAUSE 

SUGGESTED REMEDY

Input voltage is very low.

Check that the input voltage is 120-240VAC

The unit is in current limit condition not due to 
overload caused by large reactive loading or by 
the output being short circuited

Check the output terminals are not shorted. 
Remove the load. If the output loading or by 
the output being voltage gets restored, the load 
is shorted short circuited or is offering large 
reactive impedance. 

Unit is shut down due to over temp. (PSU-
1225G/1235G only)

Check that the fan has not failed or the vent 
openings for obstructions.

PROBLEM: Output voltage drops as soon as the load is switched on.

PROBABLE CAUSE 

SUGGESTED REMEDY

The unit is going into current limit protection 
mode.

Reduce the load current to less than limit 
protection mode the current limit value. Motors, 
pumps, compressors, relays, incandescent 
and halogen lamps and large capacitors in the 
input section of the DC devices draw very high 
inrush or starting currents of up to 10 times their 
normal operating currents. 
Ensure that these inrush/starting currents are 
below the current limit value of the power supply

Troubleshooting

Содержание PSU-1210

Страница 1: ...OWNER S MANUAL AC DC POWER SUPPLY Please read this manual before operating your power supply Switch Mode AC DC Power Supply Model No _______________ PSU 1210 PSU 1223 PSU 1230 _______________...

Страница 2: ...and shape as those of the original power supply plug 4 Place the unit in an area that will allow air to flow freely around the unit DO NOT block or obstruct vent openings on the side bottom of the uni...

Страница 3: ...NOTE The DC output connector has a tubular hole of diameter 0 2 5mm with a set screw For a firm connection crimp solder a pin type copper terminal on the cable ends of your 12V DC device Ensure that t...

Страница 4: ...NOT BLOCK THE OPENINGS AT THE FAN SUCTION ON THE BOTTOM AND THE DISCHARGE OPENINGS ON THE SIDES BATTERY CHARGING AND BATTERY BACK UP WARNING THESE UNITS ARE POWER SUPPLIES AND NOT BATTERY CHARGERS DO...

Страница 5: ...s are not shorted Remove the load If the output loading or by the output being voltage gets restored the load is shorted short circuited or is offering large reactive impedance Unit is shut down due t...

Страница 6: ...in accordance with the manufacturers specifications during the period of this warranty 3 The PSU Series Power Supply Unit warranty is valid for a period of 2 years from the original date of purchase P...

Страница 7: ...rrect configuration tampering un authorised repairs un authorised modification by any person acts of God corrosive environment or infestation by insects or vermin are excluded under this warranty and...

Страница 8: ...www rfiwireless com au Ph 1300 000 734 WIRELESS Warranty Department RF Industries Pty Ltd 99 Station Road Seven Hills NSW 2147...

Отзывы: