5.4 High Voltage
When operated from an AC power source this unit complies with the Australian AS/NZS 60950
equipment safety standard.
There is no surge protection built into the PSU of the FMC88108-6, so additional site specific lighting
protection, voltage surge protection and earth bonding is recommended to reduce the risk of damage.
Regarding external antennas connected to the FMC88108-6, we recommend the use of adequate coaxial lighting protection
and earth bonding through grounding kits on the RF feeder cables prior to termination into the respective RF termination
connectors on the FMC88108-6.
AC or DC mains should also be afforded surge protection.
5.5 Electro Static Discharge
Although exposure of the interconnect sockets / pins has been designed to significantly reduce the risk of
electro static discharge (ESD), precautions must be observed during installation and maintenance to protect
all the modules within the equipment.