background image

 
 
 
DSPbR Series 

– User’s Manual

 

Document Number 00000.B                                                                                                           Page 6/75 

 

Tables 

 

Page 

Abbreviations. 

 

DSPbR Generic Product Specifications 

 

8-Ch Internal Combiner Filter, per Channel Max Power Ratings 

 

dBm to RF Power in Watts – Cross Reference 

 

Ancillary Equipment and Spare Part Numbers 

 

Recommended Spares Listing 

 

 

Figures   

Page 

Typical DSPbR Functional Block Diagram 

 

DSPbR Front View 

 

DSPbR Rear View 

 

DSPbR AC PSU 

 

AC PSU Fuse location 

 

CSC Controller 

 

Ref Gen + Aux Module 

 

DSP Module 

 

RFFE & BPFM Bolted together 

 

10 

Bolting RFFE or RFBE onto BPFM 

 

11 

Cxxx8. 8-Ch Internal Combiner Filter Unit 

 

12 

Slot Allocation Architecture 

 

13 

DSPbR Dimensions – Front View 

 

14 

DPSbR Dimensions – Rear View 

 

15 

DSPbR Dimensions Right Hand Side View 

 

16 

DSPbR Dimensions Left Hand Side View 

 

17 

DSPbR Dimensions Top View 

 

18 

Sub Rack Frame M6 Earthing Stud 

 

19 

AC Mains IEC320-C19 Plug and Socket 

 

20 

DC Cable Termination Connector Phoenix HDFK16A 

 

21 

DSPbR Antenna Isolation Chart 

 

22 

Alarm Interface Circuit Diagram 

 

23 

GUI Tree 

 

24 

Ref Gen + Aux Board 

 

25 

Cell Modem Installation 

 

26 

SIM Card Installation 

 

27 

LCD Display and LED Indicators 

 

28 

Fan Cover Removal 

 

29 

User Defined Yellow Label Marking System 

 

 

Содержание DSPbR Series

Страница 1: ...Australian Provisional Patent Application No 2009905291 User s Manual Rebroadcast Repeater Booster Base Line release 1 0 DSPbR Series TM...

Страница 2: ...u Note Operation of this equipment pursuant to Part 90 of the FCC rules should be identified by selecting Part 90 Operation in the GUI Channel Configuration screen thereby limiting the per channel RF...

Страница 3: ...let Module 3 3 2 PSU Power Supply Module 3 3 3 CSC Central System Controller Module 3 3 4 Ref Gen Aux Reference Generator Module 3 3 5 DSP Digital Signal Processor Module 3 3 6 RFFE RF Front End Modul...

Страница 4: ...5 4 CSC Module Front Panel LCD Display Mode Buttons and LED s 5 5 Uploading and Downloading Firmware 6 Temperature Management 7 Alarming and Supervision 8 Firmware User s Licence Agreement 9 Maintena...

Страница 5: ...Processor DSPbR Digital Signal Processor based Repeater ETSI European Telecommunication Standards Institute GPS Global Positioning System GUI Graphical User Interface IF Intermediate Frequency MS Mobi...

Страница 6: ...9 RFFE BPFM Bolted together 10 Bolting RFFE or RFBE onto BPFM 11 Cxxx8 8 Ch Internal Combiner Filter Unit 12 Slot Allocation Architecture 13 DSPbR Dimensions Front View 14 DPSbR Dimensions Rear View...

Страница 7: ...stallations as well as regulations covering use of tools and personal protective equipment It is the responsibility of the network operator or service provider to have in place and implemented an appl...

Страница 8: ...ortion of the equipment may reach relatively high temperatures Please take the necessary precautions when servicing or removing any RFBE modules filters transmitter combiners or unscrewing any termina...

Страница 9: ...buildings large commercial business and retail buildings and shopping centres university campuses airports railways stations and sports stadiums the applications are numerous RF Industry designs and m...

Страница 10: ...ssing technology replacing traditional fixed hardware used in IF filtering such as crystal filters with software defined digital filtering providing flexibility and real time optimisation When a migra...

Страница 11: ...cket connection from either the front or rear of the sub rack This can be achieved either locally with the use of an IP Ethernet jumper cable or remotely having connected the unit into an IP Ethernet...

Страница 12: ...Auxiliary module includes GPS and optional cell modem RFFE RF Front End band specific RFBE RF Back End band specific BPFM Band Pass Filter band specific bolted to input of RFFE and output of RFBE TLM...

Страница 13: ...etwork with the cellular modem in a TCP IP session where an IP network is not available on site The DSP module is partitioned into Side A and Side B boards populated according to the number of channel...

Страница 14: ...combiner depending on type may be restricted to fixed frequencies External Duplexer Where uplink or downlink paths require combining into a single feeder network or antenna an external duplexer will...

Страница 15: ...multi racks Please consult with RFI Synthesiser Offset 0 00kHz or 6 25kHz Mode of Operation Full Duplex translating or non translating DSP channel filter profile options current 9 12 5kHz 15kHz 25 kHz...

Страница 16: ...Gated 1137W 945W Mechanical Sub Rack Frame Height 4RU Height 179mm Sub Rack Frame Depth including connectors 440mm RFFE input and RFBE output termination connectors N F Ref Gen GPS Antenna termination...

Страница 17: ...6VDC antenna termination connector SMA F Ref Gen module 10MHz clock internal reference generator GEN MON SMA F Ref Gen module 10MHz clock external reference EXT REF SMA F Ref Gen module Cellular mode...

Страница 18: ...cross different bands within the DSPbR series Expanding capability even further a single sub rack frame can be daisy chained using CAN bus interconnection to allow for additional sub rack frames to be...

Страница 19: ...larm The DSPbR hardware architecture requires a level of understanding in order for the configuration options to be understood The following sections provide an elementary explanation of the hardware...

Страница 20: ...ontroller CSC Reference Generator Ref GEN Aux Digital Signal processor DSP and at least a one RF Front End RFFE and corresponding RF Back End RFBE A BPFM is bolted onto an RFFE for insertion and or re...

Отзывы: