RF Window Co., Ltd.
| 35
ICS Repeater ICS-W0837B User Manual
ICS-
F0837 User manual/Confidential & Proprietary
2) Gain Balance set-up range is 0 ~ 10dB and this mode can be set up at the Up
Link
6.2.3. Others
At the initial execution, if Gain set-up is not executed normally, it is notified to the user and
holds the default Attenuator value
6.3. Total Power Limit
6.3.1. Objective
To give out Total Power to be less than the output power value which user wants and to
operate output power limit feature when output power is more than max. Output power set-
up
6.3.2. Procedure
1. Total Power Limit does not have additional operation Mode and it works based on
“max. output power value’ set up by user
1) Down Link Output Power set-up Range : ~ 38dBm/Total
2) Up Link Output Power set-up Range : ~ 28dBm/Total
2. Total Power Limit operating point: monitored value
≥
“max. output power set-up value
3. Total Power Limit Attenuator operating: After Down Link Attenuator change, turn down
Attenuator. To be 1 dB less than “max. output power set-up value”
1) The changed Attenuator. value should be stored in the system
2) When the changed Attenuator. value is reset
①
RCU Reset
②
Change User Attenuator. Value before changed Attenuator. value restored
4. Total Power Limit Restoration Point: Down Link Attenuator restoration condition is to
restore by 1 dB Step from 3 dB less than “max. output power set-up value”
5. Total Power Limit Restoration Attenuator operation: restore Attenuator. up to the value
of “max. output power set-up value: 2”
6. Restore preferentially the changed Attenuator. value